Section II - INSTALLATION

2.1 GENERAL INFORMATION

2.1.1

SCOPE

This section provides detailed installation and interconnection instructions for the PS Engineering
PMA8000B Audio Selector Panel/Intercom/ with internal Marker Beacon.

Please read this manual carefully before beginning any installation to prevent damage and post-
installation problems. Installation of this equipment requires special tools, test equipment (refer to section
2.12.1) and knowledge as required by 14 CFR 65.81 (b).

2.1.2

Certification Requirements

NOTE

The PMA8000B requires specialized knowledge and tools for an effective installation. An appropriately
rated Certified Aircraft Repair Station must install this equipment in accordance with applicable regula-
tions. PS Engineering, Incorporated warranty is not valid unless the equipment is installed by an author-
ized PS Engineering, Incorporated dealer.
Failure to follow any of the installation instructions, or installation by a non-certified individual or agency
will void the warranty, and may result in an unairworthy installation.

2.2 Unpacking and Preliminary Inspection

Use care when unpacking the equipment. Inspect the units and parts supplied for visible signs of shipping
damage. Examine the unit for loose or broken buttons, bent knobs, etc. Verify the correct quantity of
components supplied with the list in Section 1.6 (B). If any claim is to be made, save the shipping mate-
rial and contact the freight carrier. Do NOT return units damaged in shipping to PS Engineering. If the
unit or accessories show any sign of external shipping damage, contact PS Engineering to arrange for a
replacement. Under no circumstances attempt to install a damaged unit in an aircraft. Equipment returned
to PS Engineering for any other reason should be shipped in the original PS Engineering packaging, or
other UPS approved packaging.

2.3 Equipment Installation Procedures

2.3.1

Cooling Requirements

Forced air-cooling of the PMA8000B is not required. However, the units should be kept away from heat
producing sources (i.e. defrost or heater ducts, dropping resistors, heat producing avionics) without ade-
quate cooling air provided.

2.3.2

Mounting Requirements

The PMA8000B must be rigidly mounted to the instrument panel of the aircraft structure, within view and
reach of the pilot position(s). Installation must comply with FAA Advisory Circular AC 43.13-2B, or
other FAA-approved aircraft technical data. The unit may be mounted in any area where adequate clear-
ance for the unit and associated wiring bundle exist.

To prevent noise, avoid installing the unit close to high current devices or systems with high-voltage pulse
type outputs, such as DME or transponders. Avoid running the interconnecting bundles near any high
current wires.

2.3.3

Audio Panel Mounting Rack Installation

Remove the unit from the mounting tray by unscrewing the 3/32" hex-head screw that is in the center of
the unit. Use caution to avoid hitting the photo-detector lens. Carefully slide the unit free of the tray. Set