Audio panel tray and connector assembly, Cable harness wiring, Noise – PS Engineering PMA8000B Installation Manual User Manual

Page 9: Udio, Anel, Ray and, Onnector, Ssembly, Able, Arness

Advertising
background image

PS Engineering

PMA8000B Audio Selector Panel and Intercom System

Installation and Operator’s Manual

200-890-0101

Page 2-2

Rev. 4, April 2012

the unit aside in a safe location until needed. Install the tray using six clip nuts (475-630-0002), and six
FHP 6-32 x ½" screws (475-632-0012). The audio selector panel must be supported at front and rear of
the mounting tray.

2.3.4

Audio Panel Tray and Connector Assembly

The rack connectors mate with two 44-pin connectors in the PMA8000B. The connectors are a sub-
miniature crimp-type, and require the use a hand crimp tool, from table below (or equiv.). The connectors
are mounted to the tray back plate with #4-40 screws (475-440-1038), from the inside of the tray and the
mounting block, 431-891-0100. Ensure that proper strain relief and chafing precautions are made during
wiring and installation, using the cable clamp (625-001-0002).

Two grounding lugs are provided, which may be attached to the rear mounting plate with 2 ea #4-40 x ¼”
screws with captivated lock washers. These provide a convenient location to connect the shield ground
terminations.

Manufacturer

Crimping Tool

Positioner

Extraction tool

AMP

601966-1

601966-6

91067-1

Daniels

AFM8

K42

M24308-1

ITT-Cannon

995-0001-584

995-0001-739

91067-1

Table 2-1 Connector Pin crimping tools

2.4 Cable Harness Wiring

Referring to the appropriate Appendix, assemble a wiring harness as required for the installation. All
wires must be MIL-SPEC in accordance with current regulations. Two- and three-conductor shielded wire
must be used where indicated, and be MIL-C-27500 or equivalent specification. Proper stripping, shield-
ing and soldering technique must be used at all times. It is imperative that correct wire be used.

Refer to FAA Advisory Circular 43.13-2B for more information. Failure to use correct techniques may
result in improper operation, electrical noise or unit failure. Damage caused by improper installation will
void the PS Engineering warranty.

2.4.1

Noise

Due to the variety and the high power of radio equipment often found in today's general aviation aircraft,
there is a potential for both radiated and conducted noise interference.

The PMA8000B power supply is specifically designed to reduce conducted electrical noise on the aircraft
power bus by at least 50dB. Although this is a large amount of attenuation, it may not eliminate all noise,
particularly if the amplitude of noise is very high. There must be at least 13.8 VDC present at the connec-
tor, J2 pins 8 & 9, of the PMA8000B for the power supply to work in its designed regulation. Otherwise, it
cannot adequately attenuate power line noise. Shielding can reduce or prevent radiated noise (i.e., beacon,
electric gyros, switching power supplies, etc.) However, installation combinations can occur where inter-
ference is possible. The PMA8000B was designed in a RFI hardened chassis and has internal Electro-
magnetic Interference (EMI) filters on all inputs and outputs.

Ground loop noise occurs when there are two or more ground paths for the same signal (i.e., airframe and
ground return wire). Large cyclic loads such as strobes, inverters, etc., can inject noise signals onto the
airframe that are detected by the audio system. Follow the wiring diagram very carefully to help ensure a
minimum of ground loop potential. Use only Mil Spec shielded wires (MIL-C-275000, or better). Under
no circumstances combine a microphone and headphone wiring into the same shielded bundle. Always
use a 2- or 3-conductor, shield wire as shown on the installation-wiring diagram.

The shields can be daisy-chained together, and then connected to the ground lugs mounted on the back