5specifications, 6equipment supplied, Specifications -2 – PS Engineering DRAWS User Manual

Page 4: Equipment, Supplied -2, 5 specifications, 6 equipment supplied

Advertising
background image

PS Engineering

PRD60 Remote DRAWS Unit

Installation and Operator’s Manual

200-160-0200

Page 1-2

Rev 3, Sept. 2012

This device must accept any interference received, including interference that may cause
undesired operation.

1.5 SPECIFICATIONS

Specifications

ENVIRONMENTAL CONDITIONS:

Temperature Range:
Operating:
Storage:


-15º C to 55º C
-40º C to 85º C

Altitude:

Up to 50,000 feet in an unpressurized area of
the aircraft.

DIMENSIONS:

Height: 1.25 in. Length: 5.5 in
Width: 4.0 in . (w/ mounting flanges)

WEIGHT (With Connector):

8.5 Oz. (0.34 kg)

POWER REQUIREMENTS

Voltage:

11 to 33 VDC

Maximum Current:

750 mA (Externally protected by a 1 Amp
circuit breaker.)

Audio Specifications

Audio selector panel input impedance:

510 

Input Isolation:

-60 dB (min.)

Unswitched Audio:

4 inputs

Headphone Impedance:

150 - 1000 

Headphone Output:

38 mW into headset, no clipping into 150

Distortion:

<1% THD @ 38 mW into 150

Audio Freq. Response, 3 dB:

300 Hz - 6000 Hz

1.6 EQUIPMENT SUPPLIED

1 ea. of the following units:

Model

Part Number

PRD60

050-160- ( )