Final inspection, Inal, Nspection – PS Engineering PAC15 User Manual

Page 17: 14 final inspection

Advertising
background image

PS Engineering Inc. ®

PAC15EX Audio Selector Panel and Intercom System

Installation and Operator’s Manual

200-015-0000

Page 2-11

Rev. 1, Jan. 2014

3. Verify fail-safe operation by receiving and transmitting on com 1 from the pilot position, with the

Audio Controller power off. The Com and Unswitched #1 audio will be present in one ear cup only.

4. Apply power to the unit.

5. Check intercom operation.

6. Select COM 1 for transmitting on the MFD.

7. Verify proper transmit and receive operation from the copilot position, noting that the copilot PTT

switch allows proper transmission on the selected transceiver.

8. Verify that the Com 2 receiver to be selected and heard. Verify operation on Com 1 from the pilot

position.

9. Repeat for Com 2

10. Verify that the split mode can be invoked from the MFD, and verify that the pilot can transmit and

receive on Com 1, while the copilot transmits and receives on Com 2.

11. Verify proper operation of all receiver sources by selecting them using the appropriate means. The A1

and A2 indicators illuminate to show which navigation audio source is in use.

12. Verify that the appropriate transmit indicator is active when either push to talk is keyed.

13. Verify proper Intercom system operation in the A

LL

, I

SO

and C

REW

modes (see Table 3-1).

14. Verify that the audio selector panel system does not adversely affect any other aircraft system by sys-

tematically switching the unit on and off, while monitoring the other avionics and electrical equip-
ment on the aircraft.

2.14 Final Inspection

Verify that the wiring is bundled away from all controls and no part of the installation interferes with air-
craft control operation. Move all controls through their full range while examining the installation to see
that no mechanical interference exists. Verify that the cables are secured to the aircraft structure in accor-
dance with good practices, with adequate strain relief. Ensure that there are no kinks or sharp bends in the
cables and coaxial cables. Verify that the cables are not exposed to any sharp edges or rough surfaces, and
that all contact points are protected from abrasion.

Return completed warranty registration application to PS Engineering, or complete online at www.ps-
engineering.com.

Advertising