WARNING: Batteries produce explosive gasses, provide adequate ventilation. Extinguish
all open flames and remove all flammable’s from the area

1). After connections to the batteries have been, make sure the rate control knob is turned all the
way to LO, plug the charger into AC power, and select the HIGH or LO setting on switch In
accordance with the number of batteries connected. 3-10 on LO. 11-20 on HIGH. Increase the
charge rate until the desired setting is reached. Do not exceed 6 amps.

2). Continually monitor the line during the charging cycle. Remove any battery(s) that gases
excessively. But only after decreasing the rate control to LO, flipping the AC power off,
and unplugging from the source.

3). Depending on the condition, the size of the batteries, and charge rate, it will take anywhere
from 12-36 hours to achieve a specific gravity reading of 1.250 to 1.285 and a voltage reading
of between 14-16 volts per battery while on charge. This indicates batteries are fully charged.
NOTE: the number of batteries online does not influence the charge time.

SHUTTING DOWN CHARGER:

WARNING: Do not disconnect the charger clamps, or move any jumper lead with the
power switch on. The resulting arcing could cause the batteries to explode.

1). Turn rate control all the way to LO.

2). Flip power switch off.

3). Unplug charger.

4). Disconnect black charge lead, then red.

TROUBLE SHOOTING:

CAUTION: DO NOT DISASSEMBLE THE CHARGER. Incorrect assembly may result

in a risk of electric shock or fire. Contact factory.

DANGER: To reduce the risk of electric shock, always disconnect both the AC power
supply cord and the output leads or connector before attempting any

maintenance cleaning.