SeaLand S Series Vacuum Pump User Manual
S-series vacuum pump installation instructions
 
Dimensional 
Specifi cations
Model
Volts (DC)
Avg. Amp Draw
GPH
Fuse/Breaker
Wire Size
Weight
S12
12
6
225
10 Amp
12-14 Ga.
8 Lbs.
S24
24
3
225
5 Amp
14-16 Ga.
8 Lbs.
Before mounting the pump, you must 
consider the following:
1. Vacuum pump must be mounted
horizontally only.
2. The pump can be mounted from
2 to 15 feet from the vacuum tank. 
The maximum distance is 15 feet.
3. The vacuum pump must not be mount-
ed more than 3 feet higher than the 
vacuum tank outlet.
4. The maximum head pressure on the
discharge of the pump must not exceed 
6 feet.
Note: Two-toilet systems require a 
vacuum pump and vacuum tank for each 
toilet. It is our experience that this method 
provides the benefi t of a totally redundant 
operating toilet in case of failure in one 
toilet, and two pumps greatly reduce hose runs and system complexity.
Make sure the vacuum pump is properly located before proceeding. Place the vacuum pump on the surface to 
be mounted. Position as needed. Using a center punch, mark the four slotted holes in the pump feet. Remove 
pump.
Note: The vacuum pump emits a low frequency vibration that sometimes can produce a noticeable noise. The 
best method of isolating the pump from the mounting surface is to use SeaLand’s Noise Isolation Kit #319053. 
This kit consists of two pieces of pre-cut isolator hose and fasteners. If using Noise Isolation Kit, the pump should 
be mounted to hose isolators then the hose isolators mounted to the fl oor.
Using a 3/16-inch drill bit, drill the four mounting holes. Use a #14 wood screw to secure pump.
The fl ow direction is indicated on the pump body.
Reminder: Never mount the pump on its side, at an angle or upside down. For proper operation, the pump must 
be mounted horizontally.
Reminder: The best system will position the vacuum pump at the same level or lower than the vacuum tank and 
the vacuum tank will be positioned at the same level or lower than the VacuFlush toilet.
Stainless steel wall mounting bracket available as optional accessory – P/N 341505.
Typical One and Two Toilet Installation
Electrical 
Specifi cations
S-Series Vacuum Pump
Installation Instructions
Dometic Corporation • Sanitation Systems
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611-0038 USA
330-496-3211
1-800-321-9886 • Fax: 330-496-3097
® Registered; ™ Trademark of Dometic Corporation