8 Troubleshooting

Problem

Possible Cause

Service Instruction

1. Flush function works, but water

in bowl empties slowly or not

at all.

a. Discharge piping is pinched or

kinked.

b. Discharge piping is too high.

(Remember, all upward vertical

loops and should not exceed a

total of 4 feet (1.2 m) in height.)

c. The macerator pump or

discharge piping is blocked.

a. Check discharge piping.

b. Reroute discharge piping.

c. Close seacocks and clear

blockage.

2. Macerator pump makes

unusually loud noise or

continually trips breaker.

a. Foreign material in pump

chamber.

a. Close seacocks and clear foreign

material.

3. Flush cycle is not activated after

pushing on flush switch.

a. Holding tank is full and signal

from tank has shut down

electrical power to toilet.

b. Electrical power to toilet is shut

off or disrupted.

c. Flush switch is malfunctioning.

a. Empty holding tank.

b. Check wiring and circuit

breakers (or fuses).

c. Replace flush switch.

4. Insufficient or no water enters

the bowl.

a. Water supply line is pinched or

kinked.

b. Screen in water valve is blocked.

c. Intake water filters are blocked

(in sea water system).

d. Water valve is malfunctioning.

a. Check water supply line.

b. Clear blockage at water valve.

c. Clear water filters.

d. Replace water valve.