Caution, Notice – SIG SAUER SIG556xi User Manual

Page 21

Advertising
background image

www.sigsauer.com

21

if cycling or ejection problems are encountered due to heavy fouling, the gas valve can be moved to Position 2 by rotating
clockwise as far as the stop. in this position, a larger gas volume is released against the operating rod. The need to use the
gas valve in Position 2 is an indication that the rifle requires cleaning.

caution
-

in the case of a hot or heavily fouled weapon, use a cartridge or auxiliary aid to prevent burns to your fingers.

notice

-

firing with the gas valve in Position 2 is an exception. as soon as normal function returns, the gas valve must

be returned to Position 1. continued operation with the gas valve in Position 2 will increase recoil and

place unnecessary stress on the rifle. The rifle should be cleaned as soon as conditions permit.

waRning
- always ensure the rifle is unloaded and clear of ammunition when

manipulating the gas valve.

Advertising