Wall shield requirements for common installations, Encore 1450 non-catalytic woodburning stove – Vermont Casting 1450 User Manual

Page 17

Advertising
background image

17

Encore 1450 Non-Catalytic Woodburning Stove

30002425

Wall Shield Requirements for Common Installations

E

E

C

B

A

B

D

ST629a

Encore

wall shield AA

02/01

E

E

A = 30” (762 mm)
B = 44” (1118 mm)
C = 36” (910 mm)
D = 66” (1676 mm)
E = 1” (25 mm)

ST629a

Fig. 23 Parallel installation, vertical chimney connector,
with stove, connector and wall shields.
Maximum reduction
for both rear and side wall. Wall shields may meet at corner if
desired. A heat shield 24” (610mm) in diameter suspended 1”
(25mm) below the ceiling must surround the chimney.

A

B

C

B

A

C

ST630

Enc

Wall shield

B

02/01

A = 48” (1219 mm)
B = 36” (910 mm)
C = 1” (25 mm)

ST630

Fig. 24 Parallel installation with rear wall pass-through,
two wall shields.
Reduced clearances to both rear and side
walls. Wall shields may meet at corner if desired. Shielding for
connector is centered behind connector. Wall pass-through
must comply with codes. (See “Special Installations”)

B

C

D

A

C

ST630a

Encore

Wall shield

BB

02/01

E

F

F

A = 30” (762 mm)
B = 23” (584 mm)
C = 44” (1118 mm)
D = 66” (1676 mm)
E = 36” (910 mm)
F = 1” (25 mm)

ST630a

Fig. 25 Parallel installation with rear wall pass-through
with stove, connector and wall shields.
Wall shields may
meet at corner if desired. Connector shield extends 36” (914
mm) above flue collar, or to the elbow whichever is less.
Height “D” must be 66” (1676mm) or reach the thimble. Pass-
through must comply with codes. (See “Special Installations”.)

B

A

D

E

C

E

D

A

ST631

Encore

Wall shield

C

02/01

B

E

E

A = 29” (737 mm)
B = 45” (1143 mm)
C = 16” (406 mm)
D = 36” (910 mm)
E = 1” (25 mm)

ST631

Fig. 26 Corner installation, vertical chimney connector,
with rear, stove, connector and wall shields.
Wall shields
MUST meet at corner. Connector heat shield extends 36”
(914 mm) above flue collar. A 24” (610 mm) diameter ceiling
heat shield must surround the chimney and be suspended 1”
(25 mm) from ceiling.

B

A

D

E

C

E

D

A

ST631a

Encore

Wall shield

CC

02/01

B

E

E

A = 29” (737 mm)
B = 45” (1143 mm)
C = 16” (406 mm)
D = 36” (910 mm)
E = 1” (25 mm)

ST631a

Fig. 27 Corner installation, vertical chimney connector,
two wall shields.
Reduced side clearances. Wall shields
MUST meet at corner. A 24” (610 mm) diameter ceiling heat
shield must surround the chimney and be suspended 1” (25
mm) from ceiling.

E

E

C

B

A

B

D

ST629

Encore

wall shield

02/01

A = 30” (762 mm)
B = 48” (1219 mm)
C = 66” (1676 mm)
D = 36” (910 mm)
E = 1” (25 mm)

ST628

Fig. 22 Parallel installation, vertical chimney connector,
two wall shields.
Reduced clearances for both rear and side
walls. Wall shields may meet at corner if desired. Shielding for
connector is centered behind connector.

Advertising