Encore 1450 Non-Catalytic Woodburning Stove

30002425

Fan Kit Installation

1. Remove the sheet metal outer back shown in Figure

32.

2. Attach the fan assembly at the bottom edge of the in-

ner back with two (2) 1/4-20 x 3/4” hex head screws
and one (1) 1/4” star washer.

3. Attach snapstat to the mounting holes on the un-

derside of the bottom with two (2) 1/4-20 pan head
screws.

4. Attach the rheostat holder, (provided with stove),

under the right wing of the bottom heat shield with
two (2) #10 sheet metal screws.

5. Attach the rheostat to its holder by inserting the

rheostat control shaft through the holder hole. Install
the retaining ring and rheostat onto the shaft.

6. Secure the rheostat cable to the underside of the

bottom heat shield using the wire tie provided on the
hole at the right rear edge of the heat shield.

7. Fan will not operate until stove reaches approximate-

ly 109°F.

8. Replace the sheet metal outer back.

Fig. 32 Fan installation (Kit # 2767).

�����
�����������
����

Rheostat

Knob

Rheostat

Snapstat

Screws

ST848