16

I N S T R U C T I O N M A N U A L • M O D E L 1 5 9 5 / 1 5 9 6

O P E R A T I O N

ACTUATION

The 1595 press is equipped with two maintained anti-repeat (non-tie-down)

palm buttons, one located on the left and one on the right side of the base of

the press. Both palm buttons must be pressed simultaneously to activate the

press to cycle the welder. To operate the press, follow these simple steps:

1. Make sure the column clamps are locked.

2. Depress both black palm buttons simultaneously.

3. Once the horn comes in contact with the part and the ultrasonics are

activated, release the palm buttons. If you release the buttons before

contact is made, the head will immediately return to its “home” position.

The operation of the 1596 actuator is controlled by the automated system. A

four-wire actuation cable is provided which ties into the output side of a PLC,

or other system controlling device. Momentary two wire closure from a dry

source will initiate the welder’s cycle. For more information, refer to the power

supply manual and the included wiring diagrams.

EMERGENCY STOP

To abort the 1595 press during welding, simply press the red EMERGENCY

STOP button located at the front center of the press base.

Once the EMERGENCY STOP button has been depressed, the head will

retract and return to its “home” position, remaining there until the button is

released. Simply rotate the EMERGENCY STOP button to the right 1/4 turn

to release the press for further operation.

For the 1596 actuator, a four-wire actuation cable contains two normally

closed wires which control the emergency stop function. For more

information, refer to the power supply manual and the included wiring

diagrams.

NOTE: Power supply

cannot be shut off once

the weld cycle has

started. Termination of

cycle can only be

achieved by using the

EMERGENCY STOP

button.

The equipment has

safety devices that

require both hands to

be on the palm buttons

until the horn contacts

the workpiece. Do not

defeat or modify

these safety devices.

Do not use with a

footswitch unless

alternate means of

pinch-point protection is

provided.