Sonics 1096 Actuator User Manual

Page 15

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

14

I N S T R U C T I O N M A N U A L • M O D E L S 1 0 9 9 / 1 0 9 6

the horn contacts the part. Tighten the clamps.

4. Loosen the cap screws on the converter housing door and gently rotate the

head and horn as required to ensure proper horn-to-part alignment.

5. Lock the two column clamps, tighten the converter housing door screws,

and then tighten the fixture on the base plate.

6. Check for proper mating of fixture, parts, and horn. If the horn and part are

not in parallel contact, shim the fixture or adjust leveling screws as

required.

7. Set the PRESSURE regulator to a reading of 20 psig (140 kPa/1.4 bar) on

the pressure gauge. (Turn the PRESSURE knob clockwise.)

8. To check that the horn and parts are properly aligned, the horn needs to

be lowered. Read through the Operation instructions on page 16, and then

proceed to lower the horn as detailed. If the horn and parts are not

sufficiently aligned, then repeat steps 4 through 8. However, if you are

working with small, delicate parts, then fine adjustments can be made

using the positive stop adjustment knob as explained on page 15.

FOR THE 1096 PRESS, FOLLOW THE INSTRUCTIONS
BELOW:

The operation of the 1096 actuator is controlled by the automated system.

Rotate the stack assembly as required to ensure proper horn-to-part

alignment. Check for proper mating of the fixture, parts and horn. If the horn

and part are not in parallel contact, shim the fixture or adjust leveling screws

as required.

To check that the horn and parts are properly aligned, the horn needs to be

lowered. If necessary, shim the fixture or adjust the leveling screw again. Fine

adjustments can be made using the positive stop adjustment knob as

explained on the next page.

When the air pressure is

decreased, the converter

housing can drop down to

its limit, so be sure to

either support it or remove

anything in its path.