I N S T R U C T I O N M A N U A L • M O D E L S 1 0 9 9 / 1 0 9 6

UPPER LIMIT SWITCH

The optional Upper Limit Switch is used as a safety interlock in automation to

prevent the movement of material handling equipment (indexing) when the

horn is down. It also initiates the movement of material handling equipment

when the horn is up.

The Upper Limit Switch is factory set and should be suitable for all

applications. If for some reason you need to readjust it, observe the following

procedure:

1. Maintain air pressure and unplug the power supply from the electrical

source.

2. Remove the four screws holding the five-sided cover.

3. Loosen the jam nut holding the 8-32 cap screw in place.

4. Rotate the cap screw counter-clockwise (down) until the Upper Limit

Switch closes.

5. Tighten the jam nut to lock cap screw in position.

6. Replace the cover and four screws.

The Upper Limit Switch is now set.