I N S T A L L A T I O N

ELECTRICAL POWER REQUIREMENTS

The power supply requires a fused, single-phase, standard 3-terminal

grounding type receptacle capable of supplying the requisite voltage and

current. Refer to the table below for power specification.

SETTING UP

The power supply is a free-standing assembly. It should be installed in a

clear, uncluttered location that is free from excessive dirt, dust, corrosive

fumes, and temperature and humidity extremes. The selected installation site

should be near the electrical power source and away from equipment that

generates abnormally high electrical transients. Observe the following

additional instructions when installing the equipment:

a. Allow at least 6 inches (152.4mm) at the rear of the power supply for cable

connections.

b. Position the power supply so that the front panel controls are visible and

readily accessible.

c. The power supply is air cooled; allow sufficient space around the

assembly to ensure adequate ventilation. If the power supply must be

housed in a confined space, forced air cooling may be necessary to keep

surrounding air within acceptable ambient temperature limits. Periodically

check the ventilation grille and clean as necessary.

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T R U C T I O N M A N U A L • M O D E L G X C / G C P O W E R S U P P LY

9

The line cord of the

controller/power supply

is equipped with a 3-

prong, grounding plug.

Do not, under any

circumstances, remove

the ground prong. The

plug must be plugged

into a mating 3-prong,

grounding type outlet.

POWER SPECIFICATIONS

NOTE: If power supply

is to be run

continuously, air cooling

of the converter and

horn is required. Use

clean, dry compressed

air filtered down to 5

microns (supplied to

converter fitting – see

page 11).

Power Rating/

Model

Frequency

115 vac

230 vac

GXC400-40

400w - 40 kHz

15 amps

10 amps

GXC800-40

800w - 40 kHz

15 amps

10 amps

GXC1200-20

1200w - 20 kHz

15 amps

10 amps

GXC1700-20

1700w - 20 kHz

N/A

20 amps

GXC2200-20

2200w - 20 kHz

N/A

20 amps

GXC3500-20

3500w - 20 kHz

N/A

30 amps

GXC2200-15

2200w - 15 kHz

N/A

20 amps

GXC3500-15

3500w - 15 kHz

N/A

30 amps

GXC4500-15

4500w - 15 kHz

N/A

30 amps