STARTING UP THE POWER SUPPLY

Press the ON/OFF key to turn the power supply on. The LCD screen will

briefly display “Start Sequence” and show wattage and frequency

information. Then the LCD screen will show the following “ready” display:

INITIAL OPERATION

After the power supply is turned on (as described on previous page), follow

these steps:

1. Make sure that all necessary preparations have been made with regard to

the ultrasonic system and tooling, and that the items to be welded are in

position.

2. Press and hold the TEST button. While depressing the TEST button,

check the LCD display. Make sure the bar graph indicator on the LCD

display (a series of vertical lines that register to the 0 to 100% load meter

scale – see example below) does not exceed 20%.

During the testing process, keep in mind that the ultrasonics are only

activated as long as the TEST button is depressed – once you release the

TEST button, ultrasonics is terminated.

A bar graph indicator reading of above 20%, signals that there may be a

problem with the stack. Check your assembly and re-test.

3. The power supply is now ready for operation.

Frequency Display

The TEST key can also be used to display the running ultrasonic frequency

being used by the system. Refer to page 20 for more information.

NOTE: The TEST and

Load Meter check

should always be done

for all cold start-ups,

and for any start-up after

the system has been idle

for 20 minutes or more.