Model number nomenclature – Carrier AQUAZONE 50KQL-1PD User Manual

Page 4

Advertising
background image

4

Model number nomenclature

5

0

K

Q

L

0

7

S

A

E

C

1

0

1

A

A

Aquazone™ High-Efficiency R-22
Water Source Heat Pump
50KQL – Console Unit

Size – Nominal Capacity (Tons)
07 –

1/2

09 –

3/4

12 –

1

15 –

1 1/4

19 –

1 1/2

Power Termination
A
– Field-Connected Hard Wired
B – 20A Plug and Cord**
D – Disconnect switch, 15A fuse
F – Disconnect switch, non-fused
H – 20A Plug, Cord, Receptacle,

Disconnect Switch, 15A Fuse

K – 20A Plug, Cord, Disconnect

Switch, No Fuse

Packaging
1
– Domestic

Revision Code
0
– Current revision

Power Supply
1
– 115V-1 Ph-60 Hz††
3 – 208/230V-1 Ph-60 Hz
4 – 265V-1 Ph-60 Hz**

Heat Exchanger and Operating Range
C
– Copper heat exchanger, standard range

(60 to 95 F)

E – Copper heat exchanger, extended range (20 to 110 F)
F – Cupronickel heat exchanger, extended range

(20 to 110 F)

N – Cupronickel heat exchanger, standard range

(60 to 95 F)

Cabinet, Subbase and Mute Package Options

Std

Mute

Cabinet

Subbase

A

T

Bottom return

3 in. Subbase

B

U

Bottom return

3 in. Subbase with
Motorized Damper

C

V

Bottom return

5 in. Subbase with
Motorized Damper

D

W

Bottom return

NO BASE

E

Y

Bottom return

3 in. Subbase

Locking control door

F

Z

Bottom return

3 in. Subbase with

Locking control door

Motorized Damper

G

1

Bottom return

5 in. Subbase with

Locking control door

Motorized Damper

H

2

Bottom return

NO BASE

Locking control door

J

3

Front return

NO BASE

K

4

Front return

NO BASE

Locking control door

L

5

NO CABINET

3 in. Subbase

M

6

NO CABINET

3 in. Subbase with
Motorized Damper

N

7

NO CABINET

5 in. Subbase with
Motorized Damper

P

8

NO CABINET

NO BASE

Q

9

NO CABINET

5 in. Subbase

R

0

Bottom return

5 in. Subbase

S

O

Bottom return

5 in. Subbase

Locking control door

Water Supply Orientation

*

R – Right Hand
L – Left Hand

Water Circuit Options

Connection Type

Valve Option

A –

Sweat

2-Way Water Control Valve

B –

Sweat

Autoflow Regulator, 2.25 gpm/ton

C –

Sweat

Autoflow Regulator, 3.0 gpm/ton

D –

Sweat

2-Way Water Control Valve with
Autoflow Regulator, 2.25 gpm/ton

E

–

Sweat

2-WayWater Control Valve with
Autoflow Regulator, 3.0 gpm/ton

F

–

FPT

None

G –

FPT

2-Way Water Control Valve

H –

FPT

Autoflow Regulator, 2.25 gpm/ton

J

–

FPT

Autoflow Regulator, 3.0 gpm/ton

K –

FPT

2-Way Water Control Valve with
Autoflow Regulator, 2.25 gpm/ton

L

–

FPT

2-Way Water Control Valve with
Autoflow Regulator, 3.0 gpm/ton

M –

MPT

None

N –

MPT

2-Way Water Control Valve

P

–

MPT

Autoflow Regulator, 2.25 gpm/ton

Q –

MPT

Autoflow Regulator, 3.0 gpm/ton

R –

MPT

2-WayWater Control Valve with
Autoflow Regulator, 2.25 gpm/ton

S

–

Sweat

None

T

–

MPT

2-Way Water Control Valve with
Autoflow Regulator, 3.0 gpm/ton

*

Right and left hand orientation is determined by looking at front of unit.

†

For these options, unit must be hard wired (digit 15 must be “A”).

Control Options

A –

Manual Changeover with Complete C

B –

Manual Changeover with Deluxe D

C –

Auto Changeover with Complete C

D –

Auto Changeover with Deluxe D

P –

PremierLink™ DDC Control†

R –

Remote Thermostat with Complete C

S –

Remote Thermostat with Deluxe D

*Right and left hand orientation is determined by looking at front of unit.

†Available with Complete C only.

**20A plug and cord not available for 265V units.

††Sizes 07,09,12 only.

Advertising