ERROR CODE

CAUSE

REMEDY

5.0 TASC ERROR MESSAGES, COMMON CONDITIONS AND SOLUTIONS

FIRST Check the battery connections, this is the MOST common fault.

A required constant is set to zero.

Sometimes this is caused by poor power
connections at the battery.

Liquid servo valve is fully open, traveling
too fast for desired application.

Nozzles too small for rate, speed and
boom width. (boom pressure reads HIGH).

Too much product being diverted to
sparge.

Strainer or nozzle screens plugged.
Boom pressure LOW, main strainer; boom
pressure HIGH, nozzle screens.

Servo valve is fully open, traveling too fast
for desired application.

Hydraulic strainer plugged.
Pressure LOW indicates main strainer;
pressure HIGH indicates strainer upstream
from valve.

Hydraulic oil temperature too high.

Low hydraulic oil.

Worn hydraulic pump or motor.

Bin running at 100% power, cannot
meet target rate.

Err 0, Pump ?: reset Cal# for that channel. An
Err 0, Pump C shuts down the TASC system.
On any other channel, only the affected channel
is shut down.

Err 0, Dist. Cal#: reset distance Cal#.

Err 0, Boom #: reset boom widths (including
boom width C.

Slow down, or check hydraulic flow to a
hydraulically driven pump.

Change to larger nozzles.

Reduce sparging or turn up product pump
output.

Clean screens.

Slow down.

Increase gate height and adjust cal. #.

Increase hydraulic flow if adjustable.

Clean screens (replace filter elements).

Check Oil cooler for blockage, check tempera-
tures and oil levels.

Check oil levels and refill as necessary. Be
sure to use clean oil.

Check hydraulic pump or motor output and
rebuild or replace as necessary.

Slow down or change to higher rate feed rollers
(be sure and change Cal #).

Check for obstructions or chunks in the bin
which may be putting too high a load on the

Err 0

Err 1
PUMP-C, L
(PUMP 1, 2, 3 -
"Flow Mode")

(Flashing "Too
Fast")

(Liquid Product)

Err 1
PUMP-C, L, 1,
2, 3

(Flashing "Too
Fast")

(Granular
Product)

Err 1
PUMP-1, 2, 3
Granular bins