3.6.2 OVERRIDE CHANNEL L CONTROL
Select the L & CHEMICALS, Appl. Rate position on the display selector switch while in the SET-UP mode.
Switch the channel L rate switch to the center ON position. Use the DEC switch to zero the channel L
application rate. Switch the mode selector to OPERATE. The display will show "Flow Contl OFF Auto".
Channel L flow control valve will now respond to toggling of the INC/DEC switch. INC opens the valve and
DEC closes the valve. The switch must be held for a few seconds for the valve to open or close all the way.
To escape from this condition, enter an application rate for channel L. TASC will then perform normally.
ContL
Flow
Pump
OFF Auto