TASC 6200/6500

6.4 SETTING THE SPLIT DRIVE OPTION

Each TASC control channel has the option of operating in either standard or split drive. Split drive is used
to control a channel when changes in boom settings do not affect the drive speed of the controlled shaft
or motor. An example is a split conveyor with two separate drive motors feeding a two boom granular air
delivery applicator.

If you can't decide whether to use split drive or standard on a particular control channel, contact your
MID-TECH supplier, or the factory, for help.

A. Use the following switch settings to change from standard to split drive (you should have to
do this only once).

Power OFF
Mode selector SET-UP
Display selector L & CHEMICALS, APPL. RATE
Booms and pumps OFF
Turn the power on while holding the INC switch UP

The display will show an Err message when power up is finished.

B. Turn the desired channel rate switch ON and the display will show which drive configuration is
set (Stnrd for standard or SPLit for split).

C. Select the desired configuration by holding the INC switch UP. The display will shift between
standard and split. The one showing after you release the INC switch is set.

D. Repeat steps B and C for each channel independently.

E. Rotate the display selector switch or switch to the OPERATE mode to exit this function.

NOTE: Whenever a channel is set to the split drive
option, boom widths must be entered and all booms
must be ON before the calibrate number can be changed
(SEE 6.8, 6.9, and 6.10). If a boom position will not be
used it must be set to 0.