Toa VX-3000DS CE-GB User Manual

Page 18

Advertising
background image

18

5.3.1 Required number of VX-3000DS units in a 1-channel broadcasting system

The required number of the VX-3000DS Power Supply Manager units is determined depending on the

application of the system configured with the VM-3240VA, VM-3360VA, VM-3240E, and VM-3360E (hereinafter

called "VM amplifier"), and/or the VP-2241, VP-2421, VP-3304, and VP-3504 (hereinafter called "VP amplifier").

[System including Vm amplifiers only]

One VX-3000DS is required every 4 VM-3360VA/3360E amplifiers or 6 VM-3240VA/3240E amplifiers.

Below is an example showing that one VX-3000DS is used in a system including 3 VM amplifiers.

No. of VM-3360VA/3360E

1

2

3

4

5

6

7

8

9

10

No. of VX-3000DS units

1

2

3

VM LINK

DC POWER

DS LINK

VM-3240VA

VM-3240E

VM-3240E

Lead-acid Battery

VX-3000DS

VM LINK

No. of VM-3240VA/3240E

1

2

3

4

5

6

7

8

9

10

No. of VX-3000DS units

1

2

Advertising