20

Below is an example showing that 2 VX-3000DS units are used in a system including 5 VM-3240VA/3240E amplifiers.

[Required number of VX-3000DS units in a BGm/Paging system]

One VX-3000DS is required every 3 VM-3360VA/3360E amplifiers or 4 VM-3240VA/3240E amplifiers.

VM-3240E

VM-3240E

VM-3240VA

VP-3304 or VP-2241

VP-3304 or VP-2241

EXT. AMP INPUT

EXT. PA LINK

DC POWER

VM LINK

DC POWER

DS LINK

DC POWER

DS LINK

VM LINK

PA OUT

EXT. AMP INPUT

EXT. PA LINK

PA OUT

EXT. AMP INPUT

EXT. PA LINK

PA OUT

DC POWER

DC POWER

VP-3304 or VP-2241

VX-3000DS

VX-3000DS

No.4

No.1

Lead-acid Battery

Lead-acid Battery

No.5

Note
A pair of the VM amplifier and VP amplifier should be connected to the same VX-3000DS.

No. of VM-3360VA/3360E

1

2

3

4

5

6

7

8

9

10

No. of VX-3000DS units

1

2

3

4

No. of VM-3240VA/3240E

1

2

3

4

5

6

7

8

9

10

No. of VX-3000DS units

1

2

3