On the Confi guration Page, you can change the Host Name (NETBIOS name) the
device responds to. If you disable DHCP, you can set a static IP address, gateway,
subnet mask, and DNS servers. DNS servers need not be specifi ed. Once these
are set, click on “Save IP Confi g and Reboot.” The DAX will restart with the new
confi guration. You will need to key the new IP address in to the address fi eld of
your web browser to re-establish contact.

Changing Surround Delay
The surround delay can be changed on the Confi guration Page. The delay can be
set between 0 and 150ms, inclusive, with a resolution of 1ms. Select the desired
delay from the drop down menu.

The DAX allows the surround delay to be set either on the unit itself (rear panel
rotary switch) or through the web browser. The rear panel switch can be enabled
or disabled with the Local Delay Switch drop down menu. If the local delay switch
is disabled, switch adjustments will not affect the actual surround delay. If the local
delay switch is enabled, the surround delay can be adjusted from either the web
browser or the local delay switch. Whichever was adjusted last sets the delay. The
rear panel LED is lit if the local delay switch indicates the current surround delay,
whether the switch itself is enabled or not.

Output Level Adjust
The level of each DAX output may be reduced from the nominal 300mV at -20dBFS,
if desired. Use the drop down menus to set the level between 0dB and -63dB in
0.5dB steps. Each menu also allows a particular channel to be muted. Outputs
may be summed for monaural operation by setting jumpers within the unit. If the
unit is set for monaural operation, the outputs should be set as shown on page 14
to prevent output overload.

Auditorium Data
Users can specify various pieces of auditorium data. Each fi eld accepts up to 20
characters. The theater name and screen number are shown at the top of the sta-
tus page so users can quickly identify which system they are viewing.

Change Password
To change the password required to reach the confi guration screen, type the new
password in the two fi elds. The two values must match for the new password to
be accepted. Passwords are limited to 10 characters. Passwords are case sensi-
tive. Should you lose the password, a system restore (described on pg. 20) will be
required to restore the default password.

Updating Firmware
The Confi guration Page has a link to the Update Firmware page.