Chimney connections continued – Vogelzang TR002 User Manual

Page 11

Advertising
background image

VGZ-027 / 20120209.1

TR002 SHILOH™ / Page 11

Figure 17 - Chimney Construction through Roof

Figure 18 - Chimney Connection to Firebox

through Masonry Wall

CHIMNEY CONNECTIONS continued …

MANUFACTURED CHIMNEY

REFER TO CHIMNEY AND CHIMNEY CONNEC-

TOR MAKER’S INSTRUCTIONS FOR INSTALLATION
AND USE.

Use only 6” diameter listed chimney UL 103 HT.

Chimney made to this listing is High Temperature rated
to 2100 degrees Fahrenheit. Use chimney from only one
manufacturer. Never mix brands. Carefully follow the
chimney manufacturer’s stated requirements and clear-
ances. Use the chimney manufacturer’s attic guards,
roof supports, flashing and fire stops when passing
through a ceiling. Use a listed thimble when passing
through a combustible wall. Do not use makeshift com-
promises during installation. Never use a single-wall
connection pipe as a chimney!

When using a pre-existing chimney, have it’s condi-

tion and installation inspected before using. Make sure
that the chimney meets all of the UL rating requirements
listed above. Be aware that not all manufactured chim-
ney is of the UL 103 HT type.

NOTE: It is recommended that you contact a

licensed heating and cooling contractor (consult your
local yellow pages) for chimney installation.

Manufactured chimney with the proper required UL

listing is available from most home centers, hardware
stores, and HVAC supply stores.

If you have access to the internet, you may wish

to view chimney manufacturers’ information on-line.
See, www.duravent.com, www.selkirkinc.com, or
www.mtlfab.com.

VENTING TO EXISTING FIREPLACE

In some instances, people desire to convert an ex-

isting fireplace for stove use. Usually, safe connection to
an existing masonry chimney requires more work than
using a prefabricated chimney. The existing fireplace
must be closed and sealed at the damper with high-
temperature caulk, ceramic wool, or furnace cement.
Prior to installation, clean and inspect the existing flue
and smoke shelf. Installation should be designed so
the system can be dismantled for periodic cleaning and
inspection. Before conversion, make sure the existing
chimney is structurally sound, the chimney incorporates
a flue liner and make sure it is in good condition. (A flue
liner consists of clay tile that protects the brickwork of
a chimney. If a chimney does not have a liner, or it is
damaged, have it relined by a professional.

Do Not use

a chimney that is unlined or damaged!) If you have
any question regarding the condition of the chimney,
consult a qualified licensed contractor, qualified en-
gineer, competent mason, certified Chimney Sweep,

continued on next page

Advertising