Generator Maintenance - Any major generator

service, including the installation or replacement

of parts, should be performed only by a qualified

electrical service technician.

USE ONLY FACTORY

APPROVED REPAIR PARTS.

a. Bearing - The bearing used in these generators

is a heavy duty double sealed ball bearing.

They require no maintenance or lubrication.

b. Receptacles - Quality receptacles have been

utilized. If a receptacle should become cracked

or otherwise damaged, replace it. Using dam-

aged or cracked receptacles can be both dan-

gerous to the operator and destructive to the

equipment.

CLEANING

Remove dirt and debris with a cloth or brush. DO

NOT use high pressure spray to clean either the

engine or the generator. This high pressure spray

could contaminate the fuel system and the genera-

tor components.

1. Keep the air inlet screen on both the engine and

generator free of any dirt or debris to insure proper

cooling. At least yearly, remove the blower housing

on the engine and clean the chaff and dirt out of the

engine cooling fins and flywheel. Clean more often

if necessary. Failure to keep these areas clean may

cause overheating and permanent damage to the

unit.

2. Periodically clean muffler area to remove all

grass, dirt and combustible debris to prevent a fire.

3. On engine mufflers equipped with spark arrest-

ers, the spark arrester must be removed every 50

hours for cleaning and inspection. Replace if dam-

aged

TROUBLESHOOTING

PROBLEM (SYMPTOMS) POSSIBLE
CAUSES

———————————————————————

Won’t Start

*Low Oil Level.

*Fouled spark plug.

*Out of fuel.

*Start switch in Off position.

*Fuel valve turn off.

*Plugged fuel filter.

*Blown fuse in key switch

———————————————————————

Voltage too low

*Engine speed is too low.

*Generator overloaded.

*Defective stator.

*Defective rotor (field).

*Defective Capacitor.

———————————————————————

Circuit Breaker

*Defective load.

Trips

*Defective receptacle.

*Excessive Load.

———————————————————————

Voltage too high

*Engine speed is too high.

———————————————————————

Generator

*Overloaded.

overheating

*Insufficient ventilation.

———————————————————————

No output voltage

*Short in load (disconnect).

*Tripped or defective circuit

breaker.

*Broken or loose wire.

*Defective receptacle.

*No residual magnetism

(in generator).

*Defective stator.

*Defective rotor (field).

*Shorted capacitor.

*Shorted diodes on rotor.

*GFCI Receptacle tripped.

———————————————————————

GENERATOR SPECIFICATIONS

Generator manufacturer

MECC Alte Spa

Generator model number

S20FS-160A

Part number

351836-1

Rotor resistance

6.57 Ohms

Stator resistance

0.124 Ohms

Cap winding resistance

0.60 Ohms

Capacitors

31.5 mF

Capacitor part number

300323-112

ENGINE SPECIFICATIONS

Engine manufacturer

HONDA

Engine model number

GX630R

Type

VXE1 NH1

Code

653951

Spark plugs

ZFR5F (NGK)

Air filter

17210-Z6L-000

Air filter pre-cleaner

17218-Z6L-000

Oil filter

15400-RTA-004

Air Filter

16910-Z6L-003

Spark plug gap

0.030 in

Intake valve clearance

0.006 - 0.010 in

Exhaust valve clearance

0.010 - 0.012 in

Oil capacity

57 - 58 oz.