Connectivity summary information – Winco ASCO 300 Accessory Connectivity Module User Manual

Page 20

Advertising
background image

CHANGE

LETTER

ECN NO.

BY

APPD

DATE

PROPERTY OF ASCO POWER TECHNOLOGIES, L.P. USE PERMITTED FOR OUR WORK

ONLY. ALL RIGHTS OF DESIGN OR INVENTION ARE RESERVED

MANUFACTURING TOLERANCES TO BE IN

ACCORDANCE WITH ASCO PROCEDURE MP-I-003

FOR PLASTIC PARTS SEE MP-I-055

ASSEM. REF. NO.

THIRD ANGLE

PROJECTION

PROJECT NAME;

BY

DATE

DRAWN BY

CHECKED

DRAFTING

APPROVAL

FINAL

APPROVAL

SUBSIDARY DISTRIBUTION

COMPUTER GENERATED DRAWING

SCALE

FILE

_01

DWG. NO.

SIZE

SHEET

ECN

NO.

CHANGE

LETTER

BS

AE

CH

AG

AN

AV

AP

AM

AA

AC

AJ

PS

AS

AL

AR

YZ

AS

SRC

1 of 2

INTERFACE WIRING

DIAGRAM

Connectivity Communication Module

Cat. 5150

4/03

4/03

4/03

207179

B

629855

None

Visio

FLORHAM PARK, NJ USA 07932

200698

4/03

AS

SRC

A

Note: Baud rates of connectivity module and all other devices

connected to it MUST BE SAME.

Factory default settings:

IP Address 169.254.1.1

Subnet

255.255.0.0

Gateway

0.0.0.0

Laptop computer

use to configure

Connectivity Module

J3

J1

J2

CONNECTIVITY

MODULE

CAT.NO.5150

POWER
RX
TX

1 RX+
2 RX-
3 TX+
4 TX-
5 COM

J4

RS-485

Link

CH2

CH1

DIAG

Reset

TTL

Power Manager Xp

19200 bps

TTL/RS-485

Protocol:

Addressing: 1 - 32 PM

33 - 43 PM Engine

52 PM Breaker

Group 1 Controller with or w/o

Power Manager XP

9600 bps

TTL

Protocol:

Addressing:

1 - 32 CP/PM

Group 7/7A

Controller

9600 bps

RS-485

with or w/o

PM Xp

9600 bps

TTL

Protocol:

Addressing: 1 - 31

Group 5 Controller

with or w/o

Power Manager Xp

19200 bps

TTL

Protocol:

Addressing: 1 - 32 CP/PM

Ethernet crossover cable

ASCO PN 629590-006

Connect to connectivity

module J3

Connectivity Module

mode setting jumper

Connectivity Module J1 & J2 (TTL) *

ATS's,

Protocol, 19.2K/9600 Bps

ATS's,

Protocol, 9600 Bps

PM’s,

Protocol, 9600 Bps

PM's

Protocol, 19.2K/9600 Bps

PM's

Protocol, 19.2K/9600 Bps(Add. 33-43)

PM's

Protocol, 19.2K/9600 Bps(Add. 52)

Connectivity Summary Information

Connectivity Module J3 (Ethernet)

PC’s

Connectivity Module J4 (RS-485)

ATS's,

Protocol, 9600 Bps

Serial Modbus RTU Protocol, 19.2K/9600 Bps

Serial Modbus RTU Protocol, 19.2K/9600 Bps

Serial Modbus RTU Protocol, 19.2K/9600 Bps

Serial Modbus RTU Protocol, 19.2K/9600 Bps

Device Connectivity to Connectivity Module

7000 series ATS with or w/o Power Manager Xp

Series 300 ATS with or w/o Power Manager Xp

Series 900 ATS with or w/o Power Manager Xp

Power Manager Xp

Power Manager Xp at Engines

Power Manager Xp at Circuit Breakers

Supported Third Party Devices

PC - NT 4.0, Windows 2K, XP w/Internet

Explorer 5.0 or higher

LED Description

Power indication.

Green/Amber.

Data receiving status.

Data transmit status.

Link status. Green.

Client connection status.

CH1-Green, CH2-Yellow.

Diagnostics. Red.

LED Function

Green- Ethernet, Amber- RS-485 only.

Set by Factory.

Blinks to indicate receiving data from clients

Blinks to indicate transmit data to clients

Solid on indicates an active Ethernet connection

Both blinks to indicate active clients

Off indicates no error.

Short blinks and then off indicates

clients write data to server.

Solid red indicates errors.

LED label

POWER

RX

TX

LINK

CH1, CH2

DIAG

Mode jumper settings:

Ethernet Mode - on the right two pins.

Upload Mode - on the left two pins.

Connectivity Module side view and

internal mode jumper settings

Third party device

19200/9600

RS-485

Protocol:

Serial MODBUS RTU

207179

1/06

AS

SRC

B