Fig. 30 — Bleed Screw Position

Run the heat exchanger pump by energizing the

collector loop. When the air has been bled, tighten
the screw.

CONTROL ADJUSTMENTS - The same control
timing on the adjustable aquastat must be made

here as was the case for the plain water system. See

the section on “Control Adjustments” in the

“Plain Water System Start-Up” instructions for

details.

Inhibitors (Field Supplied)

— Procure an inhibitor

from local water treatment firm. Specify an

inhibitor of fungus, rust, scale, red water and

galvanic action. The stored fluid passes thru many
parts of the Solaround''''''' System composed of
different materials, each vulnerable to the effects

of these natural and chemical actions.

Add inhibitors to the water charge in thermal

storage tank. Tap water may be used if total
dissolved solids do not exceed 800 ppm. Other­
wise, dilute tap water with demineralized water to
reduce sohds below that level.

If the system is charged with antifreeze,

commercial automotive antifreeze solutions should
be used at 50% concentration to obtain the proper
inhibitor concentration.

Inhibitors will be depleted with time to a level

which may even increase corrosion rated beyond
that expected with uninhibited water. Therefore,
make bi-annual checks to test the inhibitor
strength, or replace the inhibitor, following the
manufacturer’s recommendation.

Suitable inhibitors for tap water are as follows:

1. For all copper piping systems with coated

concrete or fiberglass reinforced plastic storage

vessles, or steel vessels with plastic or rubber
liners:
NALCO 7SN-196 or equivalent. See specifica­
tion below.

Dosage: 1/4 lb per 1000 gallons (30 ppm).

2.

For systems with uncoated steel tanks plus

copper piping:

NALCO 2532 or equivalent. See specification
below.

Dosage: 2 oz per gallon.

NALCO 7SN-196 is in a highly soluble, pulverized
form.

Color............................................................ White
Odor ............................................................ None
Density ............................................. 67 Ib/cu ft
pH of 1 % Solution ....................................... 12.3
Solubility in Water @ 75°F .

. . . Up to an 8%

clear solution

Si02 .............................................................. 30%

PO4................................................................ 25%
Very slightly hygroscopic

NALCO 2532 is a water soluble, blended liquid
product containing quaternary amine and organo-
tin compounds with the following properties:

Color.................................................Light yellow
Odor ..............................................................Mild
Specific Gravity (@ 25°C) ........................ 1.016
Density (@ 25°C)............................... 8.46 Ib/gal
Freeze Point ............................................ — 1.0°C
Flash Point................................................... None
pH (Neat)....................................................... 12.2
Do not apply to potable water or

domestic

water systems. Apply this

product

only as

specified.

Solar-Assisted Heat Pump Operating Modes

System Equipment:

1. Pump Package (34 WA/GL)

2. Compressor and O.D. Coil (38HQ)
3. Tri-X Coil (28QX)

4. Indoor Fan and Electric Heater (40FS/FQ)

5. Solar Collector Panels

MODE: SOLAR ENERGY COLLECTION
Controlling Mechanism:
• Solid State differential controller located in

pump package control box. Two thermistor
temperature sensors are remotely located. One
sensing collector panel temperature (Tc) and
the other sensing storage tank temperature (Ts).