Troubleshooting chart - heating cycle – Carrier 50MQ User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TROUBLESHOOTING CHART - HEATING CYCLE

NO HEATING OR
INSUFFICIENT HEATING

CONTACTOR

OPEN

OPENING IN
POWER CIRCUIT

DEFECTIVE LOW

VOLTAGE

TRANSFORMER

REMOTE CONTROL
CENTER DEFECTIVE

CONTROL RELAY
COIL OR CONTACTS

DEFECTIVE

COMPRESSOR
WILL NOT RUN

COMPRESSOR RUNS

BUT CYCLES ON

COMPRESSOR RUNS -

INSUFFICIENT HEATING

CONTACTOR
CLOSED

COMPRESSOR
POWER SUPPLY
OPEN

LOOSE LEADS

AT COMPRESSOR

FAULTY START

CAPACITOR OR RELAY
SINGLE PHASE ONLY

COMPRESSOR
STUCK

REVERSING

VALVE

RELAY DEFECTIVE

CONTACTOR COIL
OPEN OR SHORTED

KLIXON OR OVER­
LOAD DEFECTIVE

INTERNAL

LOW LINE VOLTAGE

OVERLOAD

OR UNBALANCED
3-PHASE LINE

DIRTY FILTERS
OR INDOOR COIL

DEFECTIVE RUN
CAPACITOR
(SINGLE PHASE)

INDOOR FANS

CYCLING ON
OVERLOAD

COMPRESSOR

BEARINGS

1

DEFECTIVE FAN
MOTOR CAPACITOR

HIGH LOAD
CONDITION

1

LOOSE LEADS AT
FAN MOTOR

OVERCHARGE OR
NONCONDENSABLES

1 ■■ "

FAN MOTOR
BURNED OUT

REVERSING VALVE
JAMMED IN MID­
POSITION

LOW SUCTION
LOW HEAD

1

OUTDOOR FAN
STOPPED

—1 p

OUTDOOR

fan

RUNNING

LOOSE LEADS AT
OUTDOOR FAN

MOTOR

INTERNAL FAN
MOTOR KLIXON

OPEN

FAN MOTOR
BURNED OUT

DEFROST RELAY
N.C. CONTACTS
OPEN

DAMAGED
REVERSING VALVE

RESTRICTION IN
DISCHARGE LINE

OVERCHARGE OR

NONCONDENSABLES
IN SYSTEM

RESTRICTED
LIQUID LINE

ACCU RATER '
RESTRICTED OR
ICE CLOGGED

UNDERCHARGED

OUTDOOR COIL

^ DIRTY

OUTDOOR COIL

HEAVILY FROSTED

DEFECTIVE DEFROST

THERMOSTAT

DEFROST THERMOSTAT
IN POOR PHYSICAL
CONTACT WITH LINE

DEFECTIVE DEFROST
RELAY OR DEFROST

TIMER

REVERSING

VALVE

STUCK

BAD ELECTRICAL CON-
NECTiON ANYWHERE IN
DEFROST CIRCUIT

4 INTERNAL PRESSURE

RELIEF OPEN

STRIP HEATERS
NOT OPERATING

OUTDOOR

THERMOSTAT

DEFECTIVE

ODT SETTING
TOO LOW

CAP TUBE PINCHED
OR BULB NOT
SENSING TRUE ODT

STRIP HEATER RELAY
OR CONTACTOR

DEFECTIVE

OPENING IN POWER
CIRCUIT TO HEATER
ELEMENTS

BLOWN FUSE LINK

BROKEN HEATER
ELEMENT

OPEN (KLIXON)
OVER-TEMPERATURE
THERMOSTAT

DEFECTIVE ROOM

THERMOSTAT

(2ND STAGE)