Fig. 1 — dimensions, O r~j, Evap – Carrier 50AH024-060 User Manual

Page 2: Table 1 — physical data

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

r-5 MIN FOR
REMOVAL OF
PANEL

BOTTOM ACCESS'
PANEL (COND FAN
MOTOR

a

BLOWER, COND
COIL WASHDOWN)

CONDENSER COIL
WASHDOWN DRAIN 5

CORNER D

4'-o"

o

FPT

DIMENSIONS (ft-in.)

0'-4"-

I I

r - i -

I

I

I

I

I I

1

> \

1

1 i r -

i i i

1 1 1

" " i _ _ _ _ j i

_ _ _

1

°

/-~>COMPR !

{ '

CORNER C

1- —,

1

2-

1

-2-4"-

TgDIA (TYP 8 PLACES)

RIGGING HOLES

o r~j--1 --

CONTROL BOX

FIELD POWER SUPPLY
JUNCTION BOX

CORNERA

r-5" MIN FOR REMOVAL

\___ , OF PANEL

^EVAP

r 'COIL

■CORNER B

—0'-4"

EVAP COIL
ACCESS PANEL

UNIT
50AH

A

B

C

D

E

024

2-5

2-1%

1- 4%

1-2

1-1

036

2-4%

2-2

1- 4%

1-2

1-1

048

2-5

2-3

1-11%

1-8%

1-7%

060

2-4%

2-2%

1-11%

1-8%

1-7%

COND SECT.

ACCESS PANEL

0'-5"

I "DIA HOLE FIELD
CONTROL WIRING

coMPR

a

CONTROLS

ACCESS

PANEL

Fig. 1 — Dimensions

FILTER

CONDENSATE DRAINS (2)

0'-3"MIN FOR P-TRAP

BOTTOM ACCESS

PANEL(EVAR

■FAN MOTOR a

BLOWER, EVAR
COIL a
CONDENSATE
PAN)

FPT

- Center of Gravity

- Direction of Airflow

Table 1 — Physical Data

UNIT 50AH

024

036

048

060

SHIPPING WEIGHT (lbs) (Note 1)

600

620

700

710

OPERATING WEIGHT (lbs)

Base Unit

480

500

580

590

OPERATING CHARGE (lbs) (Note 2)

56

5.5

80

76

Refrigerant

R-22

COMPRESSOR — TYPE

Hermetic

Quantlty...Model

(1) AB5524H

(1). AV5535H*

(1).. P46

(1)...P60

Oil (oz)

32

32

76

76

HPS Setting (psig)

Cutout

426 ± 7

Reset

320 ± 20

LPS Setting (psig)

Cutout

27 ± 4

Reset

67 ± 7

CONDENSATE CONNECTION

Size (in.)...Type

Condensate Drain

%...FPT

CONDENSER FAN

Centrifugal — Direct-Drive

Centrifugal — Belt Drive

Nominal Cfm

1350

2250

2450

Maximum Rpm

1100

1500

Blower Size On.)

12 X 6

12

X

9

Pulley Pitch Diameter (in.)

Blower

None

60

60

60

Motor (Variable)

None

2 4-3 4

1 9-2 9

2 4-3 4

Motor Hp

%

%

1 0

1 5

Motor Rpm

825

1725

1725

1725

EVAPORATOR FAN

Centrifugal — Direct-Drive

Nominal Cfm

800

1200

1600

2000

Maximum Rpm

1100

1150

1050

1050

Blower Size (in.)

10

X

5

10

X 6

10

X 8

10

X 8

Motor Hp

Vs

Vi

%

%

CONDENSER COIL

Copper Tubes — Aluminum Fins

Size (L

X

H) (in.)

40

X

15

40

X

22

Number of Rows...Fins/in.

4...13.6

EVAPORATOR COIL

Copper Tubes — Aluminum Fins

Size (L

X

H) (in.)

34

X

15

34

X

22

Number of Rows...Fins/in.

4...14.4

INDOOR AIR FILTERS

Factory-Supplied Cleanable Type

Number...Size (in.)

(1) .1

CFM — Cubic Feet per Minute
FPT — Female Pipe Thread

PSIG — Pounds per Square Inch Gage

RPM — Revolutions per Minute

'Three-phase units use (1) AV5535E compressor

NOTES:

1 Shipping weights include base unit plus packaging
2. If components are to be split, additional refrigerant will be needed Refer to charging

charts found on page 5 and

6

3 If components are to be split, the maximum length of refrigerant tubing to be used is

75 ft, assuming components will be installed in same horizontal plane If components
are not to be installed in same horizonal plane, contact Carrier, Syracuse for more

information For additional piping information, refer to Carrier System Design Manual,
Part 3

Advertising