Single-Package

Water Source Heat Pumps

INDEX

Page

SAFETY CONSIDERATIONS..............................

1

INTRODUCTION...................................................

2

INSTALLATION....................................................

2-4

Step 1 — Check Equipment and

Jobsite ..................................................................

2

• UNPACKAGE UNIT
• INSPECT EQUIPMENT
• COMPLETE OR CONSIDER THESE

SYSTEM REQUIREMENTS

Step 2 — Connect Supply Ductwork.................

2

Step 3 — Make Piping Connections..................3

• CONNECT WATER SUPPLY AND

RETURN LINES

• INSTALL BALANCING VALVES
• INSTALL WATER REGULATING

VALVES

Page

• MAKE CONDENSATE DRAIN LINE

CONNECTION

Step 4 — Make Electrical Connections.. 3,4

• INSTALL A BRANCH CIRCUIT

DISCONNECT PER NEC

• BRING POWER LEADS INTO UNIT
• CONNECT GROUND LEAD TO

GROUND LUG IN SPLICE BOX

• SET FAN MOTOR SPEED
• CONNECT CONTROL POWER WIRING

START-UP............................................................ 4
SERVICE...............................................................6

MAINTENANCE..................................................

10

SAFETY CONSIDERATIONS

Installation and servicing of air conditioning

equipment can be hazardous due to system pressure
and electrical components. Only trained and quali­
fied service personnel should install, repair or

service air conditioning equipment.

Untrained personnel can perform basic mainten­

ance functions of cleaning coils and cleaning and
replacing filters. All other operations should be

performed by trained service personnel. When
working on air conditioning equipment, observe
precautions in the literature, tags and labels
attached to the unit and other safety precautions
that may apply.

Follow all safety codes. Wear safety glasses and

work gloves. Use quenching cloth for brazing
operations. Have fire extinguishers available for all
brazing operations.

WARNING; Before performing service or
mabiienaace operations oa system, turn off
rsi^ swsidr io sodoor anti and oatdoor
onit, Tam acces&oiy Sweater power switch if
applicate.