Locate door control within sight of door, at a minimum
height of 5 feet where small children cannot reach,

away from moving parts of door and door hardware.

If installing into drywall, drill 5/32" holes and use the

anchors provided. For pre-wired installations (as in new

home construction), it may be mounted to a single gang
box (Figure 2).

1. Strip 1/4" of insulation from one end of bell wire and

connect to the two terminal screws on back of door
control by color: white to 2 and white/red to 1.

2. Pry off cover along one side with a screwdriver blade

(see Figure 1). Fasten with

6ABx1-1/4" self-tapping screws (standard installation)
or 6-32x1" machine screws (into gang box) as follows:

• Install bottom screw, allowing 1/8" to protrude above

wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Drill and install top screw with care to avoid

cracking plastic housing.

Do not over tighten.

• Insert top tabs and snap on cover.

3.

(For standard installation only)

Run bell wire up

wall and across ceiling to motor unit. Use insulated

staples to secure wire in several places. Be careful
not to pierce wire with a staple, creating a short or

open circuit.

4. Connect the bell wire to the terminal screws on the

motor unit panel: white to 2; white/red to 1.

5. Position the antenna wire as shown.

6. Use tacks or staples to permanently attach

entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.

DO NOT connect power and operate opener at

this time. The trolley will travel to the full

open

position but will not return to the

dose

position

until the sensor beam is connected and properly

aligned.

INSTALLATION STEP 6

Install the Door Control

Aik WARNING

To prevent possible SERIOUS INJURY or DEATH from

electrocution:

• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a

closing garage door:

• Install door control within sight of garage door, out of

reach of children at a minimum height of 5 feet, and

away from all moving parts of door.

• NEVER permit children to operate or play with door

control push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is

properly adjusted, and there are no obstructions to door

travel.

• ALWAYS keep garage door in sight until completely

closed. NEVER permit anyone to cross path of closing
garage door.

Outside Keylock Accessory Connections

To opener terminal screws: white to 2; white/red to 1

HARDWARE SHOWN ACTUAL SIZE

&

I

I

I

I

I

6AB

X

1-1/4" Screw

Control Console (std installation)

3

l l l l l l l l l l l l l l l l l l l

6-32

X

1 " Screw

Control Console (pre-wired)

Insulated

Staples

Dry Wall Anchors

Figure 1

REMOVE

&

REPLACE COVER

To Replace,

InsertTop

Tabs First

Figure 2

''

.

''

24 Volt
2-Conductor
Bell Wire in
Gang Box

Advertising