Install The Safety Reversing Sensor

The safety reversing sensor must be connected

and aligned correctly before the garage door

opener will move in the down direction.

IMPORTANT INFORMATION ABOUT

THE SAFETY REVERSING SENSOR

When properly connected and aligned, the sensor
will detect an obstacle in the path of its electronic
beam. The sending eye {with an orange indicator
light) transmits an invisible light beam to the
receiving eye (with a green indicator iight). If an
obstruction breaks the light beam while the door is
closing, the door will stop and reverse to fuii open
position, and the opener lights will flash 10 times.

The units must be installed inside the garage so that
the sending and receiving eyes face each other

across the door, no higher than 6" above the floor.
Either can be installed on the left or right of the door
as long as the sun never shines directly into the
receiving eye lens.

The mounting brackets are designed to clip onto the
track of sectional garage doors without additional

hardware.

INSTALLATION STEP 10

A WARNING

• Be sure power is not connected to the garage door

opener BEFORE installing the safety reversing sensor.

• To prevent SERIOUS INJURY or DEATH from a closing

garage door:

- Correctly connect and align the safety reversing

sensor. This required safety device MUST NOT be
disabled.

“ Install the safety reversing sensor so beam is NO

HIGHER than 6" above garage floor.

If it is necessary to mount the units on the wall, the

brackets must be securely fastened to a solid
surface such as the wall framing. Extension brackets

(see accessories) are available if needed. If
installing in masonry construction, add a piece of

wood at each location to avoid drilling extra holes in

masonry If repositioning is necessary.

The invisible light beam path must be unobstructed.

No part of the garage door (or door tracks, springs,
hinges, rollers or other hardware) may interrupt the

beam while the door Is closing.

Facing the door from inside the garage