Leakage checkpoints, Caution – Sears KENMORE POWER MISER 153.336431 User Manual

Page 21

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Leakage Checkpoints

Use this guide to check a "Leaking" water heater. Many

suspected "Leakers" are not leaking tanks. Often the
source of the water can be found and corrected.

If you are not thoroughly familiar with gas codes your

water heater, and safety practices, contact the Sears

Service Center to check the water heater.

CAUTION

Read this manual first. Then before checking the water
heater make sure the gas supply has been turned "OFF

- " befoi ■

and never turn the gas "ON" before the tank is complete­
ly full of water.

CAUTION

Never use this water heater unless it is completely filled

with water. To prevent damage to the tank, the tank must
be filled with water. Water must flow from the hot water
faucet before turning "ON" gas to the water heater.

Water at the draft hood is water vapor which has
condensed out of the combustion products. This is
caused by a problem in the vent Contact the Sears
Service Center.

*Condensation may be seen on pipes in humid
weather or pipe connections may be leaking.

*The primary anode rod fitting may be leaking.

®

Small amounts of water from temperature-pressure

relief valve may be due to thermal expansion or high

water pressure in your area.

♦The temperature-pressure relief valve may be leak­

ing at the tank fitting.

Water from a drain valve may be due to the valve

opened slightly.

♦The drain valve may be leaking at the tank fitting.

Combustion products contain water vapor which can
condense on the cooler surfaces of the tank. Droplets
form and drip into the fire or run on the floor. This is
common at the time of startup after installation and
when incoming water is cold.

Water in the water heater bottom or on the floor may

be from condensation, loose connections, or the
relief valve. DO NOT replace the water heater until
a full inspection of ail possible water sources is made
and necessary corrective steps taken.

Leakage from other appliances, water lines, or
ground seepage should also be checked.

♦To check where threaded portion enters tank, insert Q-Tip between jacket opening and fitting. If cotton is wet, follow

Draining instructions and then remove fitting. Put pipe dope or teflon tape on the threads and replace. Then follow “Filling

the Water Heater" instructions in the "Installing the New Water Heater" section.