WHITE-RODGERS

1E30-373

LOW VOLTAGE THERMOSTAT

INSTALLATION INSTRUCTIONS

This low voltage room thermostat has open on rise switch
action and is designed for use on various types of heating

plants. It is equipped with a adjustable heater which may be
adjusted for primary control current draws of .15 to 1.0
Amps. A locking cover and kit of 4 alien screws and wrench is
provided to prevent tampering.

SPECIFICATIONS

Switch Rating:

Heating: 1.0a at 30vac max.
Heating Anticipator; .15 to 1.0a

Range: 35°F to 75°F

SELECTING LOCATION

The proper location of the room thermostat is most

important to insure that it will provide a comfortable home

temperature. Observe the following general rules when
selecting a location:

‘1. Locate it about 5 ft. above the floor.

2. Install it on a partitioning wall, not on an outside wall.

3. Never expose it to direct light from lamps, sun, fireplaces,

etc.

4. Avoid locations close to doors that lead outside, windows,

or adjoining outside walls.

5. Avoid locations close to radiators, warm air registers, or in

the direct path of heat from them.

6. Make sure there are no pipes or duct work in that part of

the wall chosen for the thermostat location.

7. Never locate it in a room that is warmer or cooler than the

rest of the home, such as the kitchen.

8. The living or dining room is normally a good location,

provided there is no cooking range or refrigerator on
opposite side of wall.

ROUTING WIRES TO LOCATION

1. Before drilling hole in wall at selected location, take up

quarter round and drill a small guide hole for sighting.

From basement, drill 3/4” hole in partition floor next to

guide hole. (On basementless houses, drill 1/2” hole
through ceiling above partition.)

Probe for obstructions in the partition. Then drill 1/2” hole

through wall at selected location.

___

--------------- —----------------------------------- MOUNTING THERMOSTAT

3. Through this hole in wall drop a light chain, or 6” chain

attached to a strong cord, and snag cord with hooked wire
from basement. (On basementless houses, drop cord
from ceiling and snag if at the thermostat location).

4. Attach thermostat cable to cord and pull cable through

hole in wall so that 6” of cable protrudes.

1. Pull thermostat wires through large hole in center of wall

mounting plate and fasten wires beneath two terminal

screws on bottom side of plate, (fig. 1)

2. Push excess wire into wall or switch box and plug up hole

to prevent drafts from affecting thermostat operation.

3. Thermostat must be ievei to assure optimum

performance. Place level on top of wall mounting plate
and mark hole locations for mounting screws. Attach

plate loosly to wall with the two screws provided. Again
place level on top of plate to be sure it is level. Then

tighten screws.

4. Remove cover from thermostat base by pulling outward.

Remove and discard pad (shipping protection forswitch).
Place thermostat base onto wall mounting plate and
tighten all three captive screws securely. Install
thermostat cover and tighten all four alien screws down
with wrench to prevent tampering.

Is

WHITE-RODGERS DIVISION

EMERSON ELECTRIC CO.
9797 REAVIS ROAD

ST, LOUIS, MISSOURI 63123

Printed in U.S.A.

PART No. 37-3479B

Replace 37-3479

8904