COOLING ANTICIPATION

The cooling anticipator for the 1st stage of cooling is a fixed
non-removable heater. It is for use on current draws from 0 to

1.5 Amp.

OPERATION

The chart at right shows the
different system functions with
the System and Fan Selector
switches in various positions.

1 Shows Po»itioii of Switchos

PAN

AUTO ON

STSTiM

□ □ □

COOi Off NEAT

OPERATION

■ □

□ ■ □

No heating, no cooling, no fan.

□ ■

□ ■ □

No heating, no cooling, but fan runs continuously.

□ ■

■ □ □

Cooling system cycles from thermostat.

Fan runs continuously.

■ □

■ □ □

Cooling system and fan cycle from thermostat.

■ □

□ □ ■

Heating system and fan cycle from thermostat.

□ ■

□ □ ■

Heating system turns on and off from thermostat.
Fan runs continuously.

WIRING

All wiring should be done according to local and National electrical codes and ordinances.

S.P.D.T. MERCURY SWITCH

S.P.D.T. MERCURY SWITCH

Internal Wiring

of 1F57-312

In "OFF" position,

system switch breaks

both heating and

cooling control voltage
circuits.

TRANSFORMER