Awarning, Safety instructions – Maytag HE21250S User Manual

Page 2

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Safety Instructions

AWARNING

Improper installation, adjustment, alteration, service
or maintenance can cause DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE. Refer to this manu­
al for assistance consult your local utility or call

Maytag Customer Service at 1-800-788-8899 for an

autnorized servicer for further information.

AWARNING

HAZARD OF ELECTRICAL SHOCK! Before removing

any access panels or servicing the water heater,

make sure the electrical supply to the water heater
is turned "OFF". Failure to do this could result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE.

AWARNING

HOTTER WATER CAN SCALD: Water heaters are
intended to produce hot water. Water heated to a

temperature

which

will

satisfy

clothes

washing,

dish washing, and other sanitizing needs can scald

and permanently injure you upon contact. Some
people are more likely to be permanently injured by
not water than others. These include the elderly,

children, the infirm, or physically/mentally handi­
capped. If anyone using not water in your home fits

into one of tnese groups or if there is a local code or

state law requiring a certain temperature water at
the hot water tap, then you must take special pre­
cautions. In addition to using the lowest possible

temperature setting that satisfies your hot water

needs, a means such as a mixing valve, should be
used at the hot water taps used by these people or
at the water heater. Mixing valves are available at
plumbing supply or hardware stores. Follow manu­

facturers instructions for installation of the valves.

Before changing the factory setting on the thermo­

stat, read the "Temperature Regulation" section in
this manual.

AWARNING

INSULATING JACKETS: When installing an external

water heater insulation jacket on an electric water

heater:
• DO NOT cover the temperature-pressure relief valve.
• DO NOT put insulation over the access covers or

any access areas.

• DO NOT cover or remove operating instructions,

and safety related warning labels and materials
affixed to the water heater.

AWARNING

Do not use this appliance if any part of it has been
under water. An electrical short or malfunction could

occur. The water heater should be replaced.

AWARNING

At the time of manufacture this water heater was pro­
vided with a combination temperature-pressures relief

valve certified by a nationally recognized testing labo­
ratory that maintains periodic inspection of production

of listed equipment or materials, as meeting the
requirements for Relief Valves and Automatic Gas
Shutoff Devices for Hot Water Supply Systems, and

the latest edition of ANSI Z21.22 and the code require­

ments of ASME. If replaced, the valve must meet the
requirements of local codes, but not less than a combi­
nation temperature and pressure relief valve certified

as meeting the requirements for Relief Valves and

Automatic Gas Shutoff Devices for Hot Water Supply

Systems, ANSI Z21.22 by a nationally recognized test­
ing laboratory that maintains periodic inspection of

production of listed equipment or materials.

The valve must be marked with a maximum set pres­

sure not to exceed the marked hydrostatic working
pressure of the water heater (150 Ibs./sq. in.) and a
discharge capacity not less than the water heater
input rate as shown on the model rating plate.
(Efectric heaters - watts divided by 1000 x 3415 equal
BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the

use of a temperature-pressure relief valve complying
with ANSI Z21.22 and ASME, may require a valve model
different from the one furnished with the water heater.
Compliance with such local requirements must be sat­
isfied by the installer or end user of the water heater

with a locally prescribed temperature-pressure relief

valve installed in the designated opening in the water

heater in place of the factory furnished valve.
For safe operation of the water heater, the relief valve

must not be removed from it's designated opening or
plugged.
The

temperature-pressure

relief

valve

must

be

installed directly into the fitting of the water heater
designated for the relief valve. Position the valve
downward and provide tubing so that any discharge
will exit only within

6

inches above, or at any distance

below the structural floor. Be certain that no contact is
made with any live electrical part. The discharge open­
ing must not be blocked or reduced in size under any

circumstances. Excessive length, over 30 feet, or use of
more than four elbows can cause restriction and
reduce the discharge capacity of the valve.
No valve or other obstruction is to be placed between

the relief valve and the tank. Do not connect tubing
directly to discharge drain unless a

6

" air gap is provid­

ed. To prevent bodily injury, hazard to life, or property
damage, the relief valve must be allowed to discharge
water in quantities should circumstances demand. If
the discharge pipe is not connected to a drain or other
suitable means, the water flow may cause property
damage.

The Discharge Pipe:

• Must not be smaller in size than the outlet pipe size

of the valve, or have any reducing couplings or
other restrictions.

• Must not be plugged or blocked.
• Must be of material listed for hot water distribution.
• Must be installed so as to allow complete drainage

of both the temperature-pressure relief valve, and

the discharge pipe.

• Must terminate at an adequate drain.
• Must not have any valve between the relief valve

and tank.

Advertising