Troubleshooting (cont'd)

1, Before beginning, turn “OFF” electrical power supply to

the water heater.

Esilili

A WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing

any access panels or servicing the water heater,

make sure the electrical supply to the water heater
is turned "OFF". Failure to do this could result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE.

2. Remove the two screws securing the access panel and

remove panel.

3. Open the flap of insulation to expose the opening.

4. Reset the high limit by pushing in the red button marked

“RESET”.

r®-i

Q

-RESET BUTTON

5. Fold the insulation back in place so that it completely cov­

ers the thermostat and element.

6. Replace the access panel.

7. Turn “ON” electric power to the water heater.

A CAUTION

If the high limit must be reset again, call Maytag
Customer Service at 1-800-788-8899 for an autho­
rized servicer to find out why the high limit turned

"OFF" the electric power.

NOT ENOUGH OR NO HOT WATER

1. In a new installation, the water heater may not be proper­

ly connected. Make sure the cold water supply valve is

open. Review and check piping installation. Make sure

that the cold water line is connected to the cold water
inlet to the water heater and the hot water line to the hot
water outlet on the water heater.

2. Make sure the electrical supply to your water heater is

“ON”.

3. Check for loose or blown fuses in your water heater cir­

cuit. Circuit breakers weaken with age and may not han­
dle their rated load and should be replaced.

4. Make certain the disconnect switch, if used, is in the

“ON” position.

5.

Check to see the electric service to your house has not

heen interrupted. If this is the case, contact the electric
company.

6. Are the thermostats set to the desired temperature? See

“Temperature Regulation” section.

7. If you had experienced very hot water and now no hot

water, the problem may be due to the high temperature

shut off system. See “High Temperature Shut Off
System” in the “Troubleshooting” section.

8. During very cold weather, the incoming water will also he

colder and it will require a longer time to become heated.

9.

The hot water usage may exceed the capacity of the water

heater. If so, wait for water heater to recover after abnor­
mal demand. Also examine pipes and faucets for possible
water leaks.

10. If you can not determine the problem, then call the

Maytag Service Department.

WATER IS TOO HOT

Adjust the thermostat to a lower setting. See the

“Temperature Regulation” section.