Converting the lower element (cont'd), Warning, Caution – Maytag SERIES NINE HE2940L User Manual

Page 15: Converting the lower element -15, Instructions for installation (cont'd)

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Instructions for Installation (cont'd)

Converting the Lower Element

(cont'd)

7. The wire removed from terminal 2 has a looped end. It

must remain looped and now be placed (as shown) on top
of the buss bar, over the opening of terminal

2, and secured

using the remaining screw.

8. Tighten terminals 2 and 3 to ensure proper electrical con­

nection.

11. Replace the access panel.

▲ WARNING

Failure to tighten terminal screws can cause a fire

which can result in DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.

9. Replace the terminal cover on the thermostat making sure

that the locking tabs on the terminal cover are in place.

▲ WARNING

Make sure the thermostat is flush against the tank,

the terminal cover is in place, and the insulation is

replaced. Failure to do so can result in DEATH, SERI­
OUS BODILY INJURY, OR PROPERTY DAMAGE.

10. Place the insulation block back in place so that it com­

pletely covers the thermostat and element.

12. Complete wiring to the water heater, or if completed, turn

“ON” electric power to the water heater after filling the
tank with water.

▲ CAUTION

Never use this water heater unless it is completely
full of water. To prevent damage to the tank and
heating element, the tank must oe filled with water.

Water must flow from the hot water faucet before

turning "ON" power.