Instructions for installation, Removing the old water heater, A warning – Maytag SERIES NINE HE2940L User Manual

Page 8: A caution

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Instructions for Installation

Removing the Old Water Heater

^^Turn “OFF” electrical supply to the water heater.

Turn “OFF” the water supply to the
water heater at the water shutofif valve
or water meter.

©

Attach a hose to the water heater drain
valve and put the other end in a floor
drain or outdoors. Open the water
heater drain valve. Open a nearby hot
water faucet which will relieve pressure
in the water heater and speed draining.

A WARNING

The water passing out of the drain
valve may be extremely hot. To
avoid being scalded, make sure all
connections are tight and that the
water flow is directed away from

any person.

a. If you have copper piping to the water heater, the two

copper water pipes can be cut vrith a hacksaw approxi­
mately four inches away from where they connect to
the water heater. This will avoid cutting off the pipes
too short. Additional cuts can be made later if neces­
sary, Disconnect the temperature-pressure relief valve
drain line. When the water heater is drained, discon­
nect the hose from the drain valve. Close the drain

valve. The water heater is now conapletely disconnect­

ed and ready to be removed.

b. If you have galvanized pipe to the water

heater, loosen the two galvanized pipes

with a pipe wrench at the union in each
line. Also disconnect the piping remain­

ing to the water heater. These pieces
should be saved since they may be needed

when reconnecting the new water heater.
Disconnect

the

temperature-pressure

relief valve discharge pipe. When the

water heater is drained, disconnect the
hose from the drain valve. Close the drain
valve. The water heater is now completely
disconnected and ready to be removed.

Check again to make sure the electrical supply is turned
“OFF” to the water heater. Then disconnect the electri­
cal supply connection from the water heater junction
box.

A CAUTION

Mineral buildup or sediment may have accumulated

in the old water heater. This causes the water

heater to be much heavier than normal and this
residue, if spilled out, could cause staining.

Advertising