Fig. 29—typical fan coil with 2-speed heat pump, Fig. 30—fk4c fan coil with 2-speed heat pump – Carrier WEATHERMAKER ZONEKIT2ZCAR User Manual

Page 16

Advertising
background image

→

Fig. 29—Typical Fan Coil With 2-Speed Heat Pump

A97310

RH

G

W2

W1

Y1

Y2

O

B

RC

2-SPEED

HEAT PUMP

TYPICAL

FAN COIL

C

G

W2

Y/Y2

R

C

W3

L

E

Y1

R

W2

O

W3

Y1

Y2

O

TWO-ZONE SYSTEM

See notes 1, 2, 3, 9, and 11

*

*

*

*

*

→

Fig. 30—FK4C Fan Coil With 2-Speed Heat Pump

A97311

FK4C

FAN COIL

R

R

G

W1

C

DH

W2

Y1

Y/Y2

O

C

W2

Y1

Y2

RH

G

W2

W1

Y1

Y2

O

B

RC

2-SPEED

HEAT PUMP

TWO-ZONE SYSTEM

J1 JUMPER

J2 JUMPER

O

W3

See notes 1, 2, 9, and 11

→

WIRING DIAGRAM NOTES

1. Refer to fan coil Installation Instructions for proper wiring.

2. Refer to outdoor unit Installation Instructions for latent kit requirements.

3. Terminals marked with * may not be present on equipment.

4. Interface control transformer must be in phase with furnace transformer to get high-speed fan during heat pump operation.

5. Heat pump MUST have a high-pressure switch for dual-fuel applications.

6. Two-Zone Control does not know that dual fuel is applied. Do not use thermostat AUTO CHANGEOVER mode with dual-fuel

applications, keep both thermostats in same mode (heating or cooling).

7. Configure Two-Zone Control board (jumpers) for:

(J1) T-stat = Fnc
(J3) Equipmt = HP
(J4) Fnc Ht = w/fan
(J5) LAT = Set LAT jumper high enough to allow furnace to come on during defrost and second-stage operation.
(J7) DTO = On

8. Furnace must control its own second-stage heat operation, via the furnace control algorithm.

9. Refer to outdoor equipment Installation Instructions for proper set up.

10. Select Furnace Interface option, Balance Point, and Defrost Time on 2-speed heat pump control board.

11. DO NOT select "ZONE" position on 2-speed heat pump control board. In heating mode, heat pump outdoor temperature sensor will control

the compressor low- and high-speed change.

Copyright 1997 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231

zkit8si

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

1

4

4

Tab

3a 5a 2a 5a

PC 101

Catalog No. 809-500

Printed in U.S.A.

Form ZONEKIT-8SI

Pg 16

6-97

Replaces: ZONEKIT-2SI

Advertising