Sections: laintenance

A

W ARNING

W

Before inspecting, cleaning or sermcing the machine, shut off engine, wait for all mo¥ing parts to come
to a complete stop, discomiecl spark plug wire and mo¥e wire away from spark plug. Remowe ignition
key, if so equipped.

Failure to follow these instructions can result in serious personal injury or property damage.

Stiring ¥sir Tiller

When your tiller won’t be used during the
off-season, prepare it for storage with the
following steps:

1. Clean the tiller and engine.

2. Do routine tiller lubrication and check
for loose hardware.

3. Protect the engine from deterioration
or damage by referring to the engine
storage instructions in your engine

manual literature.

4. When engine is still warm, drain oil
from engine crankcase. Refill with fresh

motor oil.

5. Protect internal cylinder against rust by
removing spark plug and pouring one
ounce of clean engine oil into spark plug
hole. Then slowly pull out recoil start
rope 2 or 3 times to distribute oil inter­
nally. Replace spark plug, but do not
reconnect plug wire. Pull rope until resis­

tance is felt — let rope rewind.

6. Charge battery {electric start option).
Store battery in cool, dry location.

7. Move Wheels/Tines/PTO Drive Lever to

NEUTRAL position. Keep tiller in a clean,
dry area.

8. Never store tiller with fuel in fuel tank
in an

enclosed

area where gas fumes

could reach an open flame or spark, or
where ignition sources are present (space
heaters, hot water heaters, furnaces, etc.).

lispecting Firwaril literlock
Wiring System

Check the Forward Interlock wiring
system every ten (10) operating hours,
for tight connections and to see that the
insulation on the wires is unbroken (to
prevent the system from shorting out).

1. Check insulated wire harness from
lower ends of handlebars to wire harness
connector on top, right side of transmis­
sion cover. Be sure connector is secure.

2. Check insulated tubing from connector
to cast iron motor mount/belt shroud.

3. Check the wire leading from the tubing
over to the switch assembly mounted on
top of the tab on the cast iron motor

mount-belt shroud. Also check the

second wire that leads to the throttle
cable mounting bracket on the right side,
forward portion of the engine.

Testing the Forward
Interlock Wiring System

The wiring circuit for the Forward

Interlock Safety System is designed to

ground out the engine’s ignition system.

There are three switches in the circuit
which, when open, let the engine run.

One switch is on the neutral plunger tab
of the cast iron motor mount. This switch
is open whenever the Wheels/Tines/PTO
Drive Lever is in NEUTRAL or REVERSE
positions. The other two switches are
located inside the handlebars, directly
above the two Forward Interlock Levers.

The switches are wired so when squeezed

(open) the engine will run. There is a

fourth switch located in the wiring
harness connector on the top, right side
of the transmission cover. It warns you if

the connection is not mated by not letting
the engine run while the Wheeis/Tines/PTO

Drive Lever is in FORWARD.

1. A broken or disconnected wire could
let the engine run without you having to
press one of the Forward Interlock Levers.

2. A bare wire touching tiller or engine

metal could ground out the engine’s
ignition.

3. A switch that has failed allows the
engine to run. Or it may prevent the
engine from running.

Refer to the

Troubleshooting

section if

your Forward Interlock Safety System is

not operating correctly.