Section 2: Assembly

ASSEMBLING THE ELECTRIC START SYSTEM

The following steps explain how to activate, charge, and Install the battery on electric start tillers. For your safety, follow all steps

and observe all accompanying safety messages. Section 5 contains other general battery maintenance and recharging instructions.

STEP 1: Activating and
Charging the Battery

IMPORTANT:

The battery Is shipped dry.

It needs battery electrolytic fluid (battery-

grade sulfuric acid). It must then be fully
charged with a battery charger before

use.

Adding electrolytic fluid to the battery and
charging the battery can be dangerous.

Electrolytic fluid contains acid that can
burn or blind you. Battery charging also
produces explosive gases.

To ensure that the battery is properly
activated and charged, you should review
these instructions with your battery
technician.

IMPORTANT:

It Is strongly recom­

mended that you have the battery

activated and charged by a trained profes­

sional (Troy-Bllt Dealer, service station,

farm equipment dealer, etc.), if you are

not experienced with these procedures.

À DANGER

A

DANGER

Battery produces explosive gases.

•Keep away sparks, flames, and

cigarettes.

• Ventilate area when charging or using

battery in an enclosed space.

• Make sure battery vent tube is always

open after battery is filled with acid.

TO ACTIVATE THE BATTERY:

I S

Battery

electrolytic

fluid

poisonous and burns severely.
Electrolytic fluid is a sulfuric acid

solution. Avoid spills or contact with

skin, eyes, clothing.

• To prevent accidents, wear protective

clothes, rubber gloves and shield

eyes with safety goggles when

working on or near the battery.

• Neutralize acid spills with a baking

soda and water solution. Neutralize

electrolyte container with same

solution. Then rinse with clear water.

• Antidote: External- Flush with water;

Eyes- Flush with water for 15 minutes

and get immediate medical attention.

•Antidote: Internal- Drink large

quantity of water or milk. Follow with

milk of magnesia, beaten eggs, or

vegetable oil. Call a doctor immedi­

ately.

A

WARNING

Remove metal jewelry before working

near the battery or near the electrical

system. Failure to comply may cause a

short circuit, resulting in electrical

burns, a shock, or battery gas

explosion.

For shipping purposes, the battery and its
hold-down ciamp (A, Figure 2-16) were
Installed backwards at the factory. When
reinstalling the battery and hold-down
clamp, be sure to face them in the
opposite direction from which they were
shipped.

Figure 2-16: Battery shown installed
backwards for shipping purposes only.

1. Remove the two 1-1/2" long screws
and the two 1/4" whiz nuts that secure the

front and rear hoid-down clamp legs to
the battery bracket (C, Figure 2-16).

Lift off the clamp and remove battery.
Save the hardware.

2.

If installed, remove and discard the

short, plastic tubing (B, Figure 2-16) that

covers the vent fitting on the negative-

side of the battery.

3. Place the battery on a level work
surface, far away from heat or flame
sources like stoves, water heaters, dryers,

and furnaces.

4.

Remove the six filler caps (D, Figure

2-17) on top of the battery.

IMPORTANT:

Be sure to wearing protec­

tive clothes, rubber gloves, and eye

protection.

5.

Fill each cell to the Upper Level line

printed on the battery case (E, Figure 2­
17) using battery-grade electrolytic
solution. (This is 1.265 specific gravity
sulfuric acid.) Temperature of battery and

electrolytic fluid is ideal when between
60°F and 80” F. Do not add water or any
other liquid to the battery during this

initial activation.

Figure 2-17: Illustration shows fiiler
caps (D) and Upper Levei fili iine (E).

6. Let battery stand for 30 minutes.
Check electrolytic fluid levei in each cell.
Add more fluid, if needed. Do not overfill

battery - this could lead to flooding from

the cells during charging.