Section 6 - Installation

INSTALLATION

PRIMEPACT 70G

and 70LP Recreational Vehicle Generators

Protect the generator against road splash and debris.

Baffles or splash guards may be required to protect cer­
tain ai'eas of the generator. To make sure the generator
is

adequately

protected,

road

test

the

installation

through mud, water and slush.

Figure 6.2

-

Typical

Suspended Mounting

System

GENERATOR MOUNTING

HOLES FOR 3/8" -16

BOLTS (BOTH SIDES)

6.2 GENERATOR COIVIPARTIViENTS

Wlrether the generator set is being installed inside a com­
partment specifically manufactured to house a generator
or inside a compartment that the installer constructs, the
compartment MUST meet certain specifications as out­
lined in the following sections:

♦ 6.2.1 COMPARTMENT SIZE________________________

Plan the compartment size carefully. Provide a mini­
mum clearance of 1/2 inch (13 mm) on the front and
top, 1 inch (25 mm) on the sides, and 1/2 inch (13 mm)

from ilic back lor air circulation AFTER the compart­
ment has been lined with metal and sound insulalioii
(Figure 6.4).

NOTE:

Refer to “Figure 5.2

-

Dimensions” on Page 21.

Major Features and

Figure 6.4

-

Clearances

•

The installer must make certain that the selected

location will permit adequate cooling and ventilating
airflow to be supplied.

♦ 6.1.4

GENERATOR RESTRAINT____________________

Use four 3/8"-16 hardened steel bolts (Grade 5) to fasten
the generator to the supporting frame or the support tub­
ing. These bolts must pass through (a) the generator
mounting base, (b) the compartment floor (if a compart­

ment

is

used)

and

(c)

the

supporting

framework

(Figure 6.3). /Ml bolts must be long enough so that when

tight, at least three threads are visible past the retaining
lock nuts. Refer to Section 6.2 for the location of the gen­
erator mounting holes.

Figure 6.3

-

Typical Generator Restraint

1/2 INCH THICK

• 6.2.2 COMPARTMENT CONSTRUaiON_______________

•

The generator compartment should be either con­

structed of, or lined with, 26-gauge galvanized steel.

NOTE:

Aluminum

is

NOT

an

acceptable

alternative

to

galvanized

steel

due

to

aluminum’s

low

melting point.

•

If the compartment is lined with galvanized steel, it

may be constructed of any material. Generac recom­
mends that the compartment be constructed of 1/2-
inch thick plywood (not strandboard), with the floor
made of a double thickness of 1/2-inch plywood with
the grain of the wood at cross section for added
strength (Figure 6.5).

Figure 6.5

-

Typical Compartment Construction

CROSS SECTION VIEW

METAL LINING

Generac* Power Systems, Inc. 23