Section 6 - Installation

INSTALLATION

PRIMEPACT 70G and 70LP Recreational Vehicle Generators

Vapor seal all compartment seams and joints.
Over the galvanized steel lining, install a combination

of acoustical materials as mentioned in Section 6.2.3.

DANGER

Figure 6.7 - Typical Noise Abatement

A

To prevent fire or explosion, do not install any

insulation or other absorbent materials on the
interior or underside of the compartment floor.

• Seal all compartment door edges to prevent noise

leakage around the door perimeter.

• Line the compartment door interior (except for air

openings)

with

suitable,

fireproof

sound

insulation

(such as 1-inch (25 mm) thick fiberglass with a 2-

pound density).

Figure 6.8

Compartment Floor Cutout