Generac IM-72LP Industria! Mobile Generator

A

Figure 2 — Connections for 120 Volts

OPERATING PRECAUTIONS

WARNING: NEVER OPERATE THE GENERATOR
SET WHILE THE VEHICLE IS PARKED OVER DRY
LEAVES, DRY GRASS OR ANY OTHER COM­
BUSTIBLE SUBSTANCE. THE GENERATORS
EXHAUST SYSTEM BECOMES EXTREMELY HOT

AND CAN CAUSE FIRE IF IT IS TOO CLOSE TO
COMBUSTIBLE MATERIALS.

WARNING: THE GENERATORS EXHAUST
SYSTEM GIVES OFF DEADLY CARBON MONOX­
IDE GAS. THIS DANGEROUS GAS, IF BREATHED
IN SUFFICIENT CONCENTRATIONS CAN CAUSE
UNCONSCIOUSNESS AND EVEN DEATH. NEVER

OPERATE THE GENERATOR SET WITH THE VEHI­
CLE INSIDE ANY GARAGE OR OTHER ENCLOSED
AREA. NEVER OPERATE THE GENERATOR WITH
A LEAKING EXHAUST SYSTEM. CLOSE WIN­

DOWS IN THE VICINITY OF THE GENERATOR
EXHAUST OUTLET AND TAKE ANY OTHER STEPS

THAT MAY BE NECESSARY TO PREVENT

EXHAUST GASES FROM ENTERING ROOMS OR

AREAS OCCUPIED BY PEOPLE OR ANIMALS.

GENERATOR CONTROL PANEL -

Mounted on the generator control panel (Figure 3) are the fol­

lowing features:

Figure 3 — Generator Control Panel

PUSE MAIN

STAFIT 'tGA

BREAKER

Fulvio?

FUEL PRIMER

Before starting a cold engine (it has not been started in more

than two weeks), you must press this switch to bring fuel from

the tank to the fuel pump. This rocker type switch springs back

into its original position when you release it.

START/STOP SWITCH

To crank and start the engine, hold this switch at its START

position. Release the switch when the engine starts. To stop

an operating engine, press and hold the switch in its STOP

position until the engine shuts off. The switch center position

is the RUN position.

FUSE

Protects the engine DC control circuit against electrical over­

load. If the fuse element has melted open due to overloading,

the engine cannot be cranked. If you must replace it, use only

an identical replacement fuse.

MAIN

BREAKER

Protects generators AC output circuit against overload and pro­

vides a method of turning CFF the generators 120/240 volts

AC output to vehicle circuits (Figure

4).

I n d u s t r i a l M o b i l e G e n e r a t o r

7