background image

Generac IM-72LP Industrial Mobile Generator

NOTE: Refer to THE GENERATOR AC CONNECTION

SYSTEM on page 4. Individual installations will differ. If an

overload occurs, the dual breaker will open the hot stator

leads (11 and 44).

When

the generator has been connected

for 120 volts only, either of the dual circuit breakers will open

stator AC output leads No. 11 and No. 33.

Figure 4 — Dual Circuit Breaker

30A.

30A.

OPTIONAL REMOTE

START/STOP PANEL

A remote mounted Start/Stop Panel is available, which allows

you to start and stop the generator engine conveniently from

inside the vehicle.

BEFORE STARTINC THE ENGINE

IMPORTANT: INSTRUCTIONS AND INFORMATION IN THIS

MANUAL ASSUME THE GENERATOR HAS BEEN PROP­

ERLY INSTALLED, CONNECTED, SERVICED, TESTED AND

ADJUSTED BY A QUALIFIED INSTALLATION TECHNICIAN

OF INSTALLATION CONTRACTOR.

INSTALLATION___________ ____

Generator installation must have been properly completed so

it complies with all applicable codes, standards and regula­

tions and with the manufacturer's recommendations.

ENGINE LUBRiCATIQN__________________

Have engine crankcase properly serviced with recommended

oil before starting. Refer to "Maintenance" and "Specifica­

tions"

sections

for

oil

servicing

procedures

and

recommendations.

CAUTION: Any attempt to crank or start the

engine before you have properly serviced it with

the recommended oil may result in engine failure.

FUEL SUPPLY

The engine must have adequate supply of proper fuel to oper­

ate. Before starting, check that sufficient fuel is available.

■ COOLING AND VENTILATING AIR

Air inlet and outlet openings in the generator compartment

must be open and unobstructed for continued proper operation.

Without sufficient cooling and ventilating air flow, the engine-

generator quickly overheats, which causes it to quickly shutdown.

Overheating could also damage the unit or your vehicle.

m

ENGINE EXHAUST GAS

Before starting the generator engine, you should be sure there

is no way for exhaust gases to enter the vehicle interior and

endangering people or animals. Close windows, doors and

other openings in the vehicle that, if open, might permit exhaust

gases to enter the vehicle.

DANGER: THE GENERATOR ENGINE GIVES OFF

DEADLY CARBON MONOXIDE GAS THROUGH ITS
EXHAUST SYSTEM. THIS DANGEROUS GAS, IF
BREATHED IN SUFFICIENT CONCENTRATIONS,

CAN CAUSE UNCONSCIOUSNESS OR EVEN
DEATH. DO NOT OPERATE THE GENERATOR IF

ITS EXHAUST SYSTEM IS LEAKING OR HAS BEEN

DAMAGED. SYMPTOMS OF CARBON MONOXIDE

POISONING ARE (A) INABILITY TO THINK COHER­

ENTLY,

(B) VOMITING, (C) TWITCHING MUSCLES,

(D) THROBBING TEMPLES, (E) DIZZINESS, (F)
HEADACHE, (G) WEAKNESS AND SLEEPINESS. IF

YOU FEEL ANY OF THESE SYMPTOMS, MOVE

INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS
PERSIST, GET MEDICAL HELP.

STARTING THE GENERATOR

To start the generator from either the generator control panel

or from the optional Remote Panel, proceed as follows:

1. Turn OFF electrical loads, using whatever means provided

in your vehicle (such as a main line circuit breaker or trans­

fer switch.

NOTE: If starting from the generator panel, turn OFF loads

by setting the generators main circuit breaker to “OFP or

“OPEN”. If starting from a Remote Panel, turn OFF loads using

whatever means is provided in the vehicle (such as a main cir­

cuit breaker).