16 troubleshooting – Nespresso Essenza FS EF 474 User Manual

Page 16

Advertising
background image

16

Troubleshooting

Service Manual EF 473 / EF 474

en

Version 1.0

4 Press On/Off button to perform
automatic self test - continued

4.1 Machine is not working (no function)
- continued

YES - g) Check if electrical wires are functional

YES - Replace electronic mainboard
NO - Replace defective(s) wire(s)

NO - Go to point 4.2

4.2 Backlighted coffee button blinks at irregular
intervals

YES - Check if thermoblock heating element is func-
tional

YES - Replace NTC
NO - Replace thermoblock

NO - Self test ok. Go to point 5

5 Check coffee temperature while
preparing a coffee (see page 30)

5.1 No coffee outlet

YES - a) Water circuit is empty

YES - Fill water circuit (see page 9)
NO - Go to point b)

YES - b) Flow meter is clogged

YES - Clean or replace it
NO - Go to point c)

YES - c) Pyramid plate is clogged

YES - Replace CBU
NO - Go to point d)

YES - d) Machine is blocked by scale

YES - Descale machine (see page 25)

NO - Go to point 5.2

5.2 Temperature is too low (less than 83°C)

YES - Descale the machine (see page 25)
NO - Go to point 5.3

5.3 Temperature is too high (more than 89°C)

YES - Change NTC
NO - Go to point 6

6 Check for leaks and check flow
rate (see pages 27, 28 and 29)

6.1 Leakage at extraction system

YES - Replace CBU
NO - Go to point 6.2

6.2 Leakage at tubes connection

YES - Replace defective tube and seal
NO - Go to point 6.3

6.3 Flow rate out of range

YES - Machine is scaled

YES - Descale machine (see page 25)
NO - Replace pump

NO - No trouble found during the check procedure.

Contact Nespresso Technical Correspondant for
further details in order to take decision.

7 Descaling process (if needed)

7.1 Machine scaled

YES - Descale machine (see page 25)
NO - Go to point 8

8 Final cleaning (see page 31)

End of check procedure

Check procedure

Symptoms

Action / repair work

Further action / repair work

Advertising