Replacing thermoblock and ntc, 18 repair – Nespresso Essenza FS EF 474 User Manual

Page 18

Advertising
background image

18

Repair

Service Manual EF 473 / EF 474

en

Version 1.0

Replacing thermoblock and NTC

Tools:
- Torx screwdrivers T10, T30
- Open-ended spanner 10 mm AF
- Torque wrench

Procedure:

1. Follow general disassembly (see page 16).
2. Remove screw (23) and detach holder

(48) with flow meter (47).

3. Remove 3 screws (23) and separate

thermoblock (40) with support (40) from
chassis.

4. Remove screw M3.5 x 25, washer and

rubber gasket and separate thermoblock
(40) from its support.

5. Remove screw (38) and separate fine wire

fuse (900) from thermoblock.

6. Remove electronic housing (28).
7. Unplug NTC connector from electronic

control board (28).

8. Remove NTC (43) from thermoblock and

replace it if defective.

9. Remove clips (13) and hose connectors

(16, 26) from thermoblock.

10. Remove ground wire and electrical

connections from thermoblock.

11. Replace defective thermoblock.

12. Assemble in reverse sequence.

)

Use a torque wrench (90 - 110 Ncm)
to tighten NTC temperature sensor
(43) with spring washer (42).

40

23

38

38

39

900

43

M3.5 x 25

28

13

26

16

23

47 + 48

40

42