Recording the slider value in a sequence, After key – Akai MPC 1000 User Manual

Page 55

Advertising
background image

MPC1000 v2 Operator’s Manual rev 1.0

45

04. In the High range field and Low range field, set the

upper and lower limit of the sliders.

The value of the controlled parameter is determined
by the value set here. The value depends on the type
of the parameter selected in the Parameter field.

TUNE :

-120 - +120 This controls the sample pitch with “10”
equals a semitone.

LEVEL : 0 –100

This control the sample volume level.

CUTOFF1+2 / CUTOFF1 / CUTOFF2 : -50 - +50

This offsets the cut off frequency of the currently
selected filter. The value set in the PROGRAM mode
is used as 0.

RESO1+2 / RESO1 / RESO2 : -50 - +50

This offsets the resonance of the currently selected filter.
The value set in the PROGRAM mode is used as 0.

LAYER : 0 - 127

This value switches layers instead of Velocity.

ATTACK : 0 – 100

The attack time of the envelope will be replaced
with this value.

DECAY : 0 – 100

The decay time of the envelope will be replaced
with this value.

Note :

When you change the LEVEL or the PAN on REAL

TIME by Q-Link slider, some noise may occur depending on

the sound.

Resetting the Q-Link slider value

You can reset (back to the original value) the altered
value of Q-Link slider.

Example : When you control the Tune of the Pad Event
with REAL TIME, the Tune will keep the changed value
after you change the Q-Link slider. If you press the [F5]
(ALL R) key or the [F6] (RESET) key, the changed value
resets to its original value.

[F5] (ALL R) :

All parameter changed with REAL
TIME resets to the original value.

[F6] (RESET) :

Only the parameter being displayed in
Slider page resets to the original value.

Recording the slider value in

a sequence

When you use the Q-Link slider while recording a sequence.
the Note Variation data will be recorded into the track of
the sequence.

When the NOTE ON is selected in the Change field,
the value of the Q-Link slider will be recorded as
Note Variation information with the Pad Event.

When the REAL TIME is selected in the Change field,
the value of the Q-Link slider will be recorded as Q-
Link event, independent of the Pad Event.

AFTER key

This key sets the operation of the Q-Link slider, when a se-
quences is recorded, the Note Variation data is played back.

The operation of the [AFTER] key is different with “NOTE
ON” or “REAL TIME” .

When the “NOTE ON” is selected,

If the [AFTER] key is OFF, (the LED is off), if you
move the Q-Link slider while playing back a se-
quence with Note Variation, the Pad’s Note Varia-
tion is played as recorded. If you hit a Pad during
playback, the Pad that you hit will have the effect
of Q-Link slider.

If the [AFTER] key is ON (the LED is lit.), if you
move the Q-Link slider while playing back a se-
quence with Note Variation, the Note Variation
value will be replaced with the current position of
the Q-Link slider.

When the “REAL TIME” is selected,

If the [AFTER] key is OFF, (the LED is off), if you
move the Q-Link slider while playing back a se-
quence with Note Variation, the recorded Pad’s
sound will be changed.

If the [AFTER] key is ON (the LED is lit.), the re-
corded Q-Link Event will be ignoreed and the cur-
rent Q-Link slider position will be used while play-
ing back a sequence with Note Variation.

While recording a sequence,

If the [AFTER] key is OFF, when you move the Q-
Link slider, the new Q-Link Event will be recorded
and added to the existing Q-Link Events.

If the [AFTER] key is ON, when you move the Q-
Link slider. The new Q-Link event will be recorded
and will erase any previous Q-Link Events.