Setting the Filter Envelope

01. In the FILTER page of PROGRAM mode, select the

pad you wish to filter by hitting it.

02. In the Type field, press the [WINDOW] key.

The Filter Envelope window will be displayed.

Pad field :

The selected pad will be displayed.

Filter field :

The selected Filter type will be displayed.

Time field :

You can set the time of the filter en-
velope. It is the time from the begin-
ning (the value set in the Amount
field) to the original cut off frequency.

Amount field :

You can set the depth of the filter en-
velope. If you set this filed to a “ + ”
value, the cut off frequency will start
higher than the original cut off fre-
quency and goes back to the original
frequency within the time set in the
Time field. If you set this filed to a “ -
“ value, the cut off frequency will start
lower than the original cut off fre-
quency and go back to the original fre-
quency within the time set in the Time
field.

V>Time field :

You can control the filter envelope
time by velocity. If you set this field
to a “ + ” value, the time will be closer
to the time set in the Time field with
higher velocity, If you set this field
to a “ - ” value, It works exactly op-
posite. If you set this field to 0, the
time is constant by velocity.

V>Amount field :

You can control the depth by veloc-

ity. If you set this field to a “ + ” value,
the beginning cut off frequency will
start closer to the frequency set in
the Amount field with higher veloc-
ity, If you set this field to a “ - ” value,
It works exactly opposite. If you set
this field to 0, the depth is constant
by velocity.

V>Freq. Field:

You can control the cut-off frequency
with velocity. The larger the veloc-
ity, the higher the cut-off frequency.
If you set this field to 0, the cut-off
frequency is constant by velocity.