BLOWER INSTRUCTIONS

INSTALLING THE VFB BLOWER (BFT201 / BFT202, BFT301 / BFT302 MODELS ONLY)

STEP 1. Remove blower assembly from shipping carton.
STEP 2. Insert blower assembly into upper back of heater (See Figure 11).
STEP 3. Secure blower to heater using three #8 screws (provided) through holes pre-punched in heater back.
STEP 4. Locate mounting holes for switchbox (See Figure 11).
STEP 5. Secure switchbox to heater using two #8 screws (provided).
STEP 6. Plug power cord into 115 volt three-prong grounded receptacle.

CAUTION:

Always unplug power cord before servicing or cleaning heater. This appliance is equipped with a three-
prong (grounding) plug for your rotection against shock hazard and should be plugged directly into a
properly grounded three prong receptacle.

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.

FIGURE 11

Switchbox

Blower Assembly

Fan
Switch

Page 14

Blower Motor

White

(or ribbed)

Green

Black

WIRING DIAGRAM / VFB BLOWER

Power
Cord

If any of the original wire supplied with
the appliance must be replaced, it must
be replaced with a wire of at least a
105

º

C temperature rating.